Vc3000 series, Installation guide, Terminals, wire identification & ratings – Viconics VC3000 Line Voltage Installation Guide User Manual
Page 6: Line voltage connections

VC3000 Series
6
Installation Guide
Viconics Technologies Inc.
I Small Building Systems I 9245 Langelier Blvd. Saint-Leonard, Quebec, Canada, H1P 3K9 I +1 514 321 5660 I www.viconics.com
028-0296-07
May 2013 bm
© 2
01
3 V
ic
on
ic
s T
ec
hn
ol
og
ie
s. A
ll r
ig
ht
s r
es
er
ve
d
.
teRMInals, WIRe IDentIFICatIon & RatInGs
Part #
VC3500E5045 VC3504E5045
VC3514E5045
Occupancy
Output
VC3400E5045 VC3404E5045
VC3300E5045
Slave Fan
Unit
Low Voltage
Terminals
No local inputs
Low voltage
inputs
Low voltage
inputs
No local inputs
Low voltage
inputs
No local inputs
1
1- Tx/Rx
1- Tx/Rx
1- Tx/Rx
1- Tx/Rx
1- Tx/Rx
1- Tx/Rx
2
2- 7 VDC
2- 7 VDC
2- 7 VDC
2- 7 VDC
2- 7 VDC
2- 7 VDC
3
3- Com
3- Com
3- Com
3- Com
3- Com
3- Com
4
4- RUI 1
4- RUI 1
4- RUI 1
5
5- Scom
5- Scom
5- Scom
6
6- RBI 2
6- RBI 2
6- RBI 2
7
7- SS
7- SS
7- SS
8
8- RS
8- RS
8- RS
9
9-Occ
9- Heat -
9- Heat -
10
10- Heat +
10- Heat +
LINE VOLTAGE CONNECTIONS
Power Supply
Power supply: - 90 to 277 VAC (universal all models)
- Black Hot L1 Power VAC (Switches: Brown, Blue, Red, and Yellow)
- White neutral power VAC
Fan line voltage
contact
Wire connection
½ HP Maximum
3 Fan Speed
Control Wires
Brown, Blue,
Red
3 Fan Speed
Control Wires
Brown, Blue,
Red
3 Fan Speed
Control Wires
Brown, Blue,
Red
3 Fan Speed
Control Wires
Brown, Blue,
Red
3 Fan Speed
Control Wires
Brown, Blue,
Red
3 Fan Speed
Control Wires
Brown, Blue,
Red
Valve line voltage
contact output
Yellow wire
connection
10A maximum
4 Pipes Cool
output
Or
2 Pipes Heat /
Cool output
4 Pipes Cool
output
Or
2 Pipes Heat /
Cool output
4 Pipes Cool
output
Or
2 Pipes Heat /
Cool output
2 Pipes Heat /
Cool output
2 Pipes Heat /
Cool output
N/A
Valve line voltage
isolated contact
output
2 x Orange wires
connection10A
maximum
4 Pipes Heat
output
Or
2 Pipes reheat
output
4 Pipes Heat
output
Or
2 Pipes reheat
output
4 Pipes Heat
output
Or
2 Pipes reheat
output
N/A
N/A
N/A
VC3300E5000
Beyond Comfort
Made in Canada
1
2
3
Power
Supply
Tx / Rx
7 Vdc
Com
STATUS
BLACK
WHITE
RED
BLUE
BROWN
FAN
LOW
FAN
MED
FAN
HIGH
90-277 Vac - 50/60 Hz
10A 1/2HP Max
Use copper conductors only.
008-0510
VC3504E5000
Beyond Comfort
Made in Canada
1
2
3
Power
Supply
Tx / Rx
7 Vdc
Com
STATUS
BLACK
WHITE
YELLOW
RED
BLUE
BROWN
COOL
FAN
LOW
FAN
MED
FAN
HIGH
90-277 Vac - 50/60 Hz
10A 1/2HP Max
ORANGE
ORANGE
HEAT
4
5
RUI 1
6
SCom
RBI 2
7
8
SS
RS
Use copper conductors only.
008-0514
VC3400E5000
Beyond Comfort
Made in Canada
Use copper conductors only.
1
2
3
Power
Supply
Tx / Rx
7 Vdc
Com
STATUS
BLACK
WHITE
YELLOW
RED
BLUE
BROWN
COOL
FAN
LOW
FAN
MED
FAN
HIGH
90-277 Vac - 50/60 Hz
10A 1/2HP Max
9
10
Heat-
Heat+
008-0511
VC3404E5000
Beyond Comfort
Made in Canada
1
2
3
Power
Supply
Tx / Rx
7 Vdc
Com
STATUS
BLACK
YELLOW
RED
BLUE
BROWN
4
5
RUI 1
6
SCom
RBI 2
7
8
9
SS
RS
10
Heat-
Heat+
008-0512
WHITE
COOL
FAN
LOW
FAN
MED
FAN
HIGH
90-277 Vac - 50/60 Hz
1/2HP + 5A Max Comb.
Amb. Temp. 50
o
C
Use copper conductors
75
o
C min. only.
5A
Max
1/2 HP
Max
VC3300E5000
Beyond Comfort
Made in Canada
1
2
3
Power
Supply
Tx / Rx
7 Vdc
Com
STATUS
BLACK
WHITE
RED
BLUE
BROWN
FAN
LOW
FAN
MED
FAN
HIGH
90-277 Vac - 50/60 Hz
10A 1/2HP Max
Use copper conductors only.
008-0510