7 grounding equipment and methods, 7 grounding equipment and methods –6 – Compaq 110 User Manual
Page 67

4–6
Maintenance and Service Guide
Removal and Replacement Preliminaries
4.7 Grounding Equipment and Methods
Grounding equipment must include either a wrist strap or a foot 
strap at a grounded workstation.
■
When seated, wear a wrist strap connected to a grounded 
system. Wrist straps are flexible straps with a minimum of 
one megohm ±10% resistance in the ground cords. To 
provide proper ground, wear a strap snug against the skin at 
all times. On grounded mats with banana-plug connectors, 
connect a wrist strap with alligator clips.
■
When standing, use foot straps and a grounded floor mat. 
Foot straps (heel, toe, or boot straps) can be used at standing 
workstations and are compatible with most types of shoes or 
boots. On conductive floors or dissipative floor mats, use 
them on both feet with a minimum of one-megohm resistance 
between the operator and ground. To be effective, the 
conductive strips must be worn in contact with the skin.
■
Other grounding equipment recommended for use in 
preventing electrostatic damage includes:
❏
Antistatic tape
❏
Antistatic smocks, aprons, or sleeve protectors
❏
Conductive bins and other assembly or soldering aids
❏
Non-conductive foam
❏
Conductive tabletop workstations with ground cord of 
one-megohm resistance
❏
Static-dissipative table or floor mats with hard tie to 
ground
❏
Field service kits
❏
Static awareness labels
❏
Material-handling packages