Step 8 – hood panels, Step 9 – hood end panel, Step 7 – hood end panel – Twin City Modular Gravity Hood - MGI with Filters - IM-4720FSS User Manual
Page 4
End Panel Assembly
-Male-
Sheet Metal Screw
IMPORTANT - This flange must be
male. Refer to Figure 9.
Step 8 – Hood Panels
Fasteners (Kit #4A and Kit #5)
Install
Hood Panels using #12 screws. Place female end of next panel over male end of end panel. See Detail A.
On sizes where hood width is 108" and larger, hood clips must be installed at each interlocking rib while installing
the panels. Position the
Hood Panel in place and reach underneath to slide the Hood Clip into place. See Detail B.
Step 9 – Hood End Panel
Fasteners (Kit #4A) –
Note: There may be extra fasteners.
Install
Female End Panel Assembly using #12 screws. Fully tighten the Hood Mount Bar/Side Rail fasteners from
Step 6.
End Panel Assembly
-Female-
Figure 11.
Step 7 – Hood End Panel
Fasteners (Kit #4A and Kit #5) –
Note: There may be extra fasteners.
Install
Male End Panel Assembly using #12 screws.
Figure 8.
Figure 9.
End Panel Assy,
Male
IMPORTANT
- This flange must
be male. Refer to the detail below.
Male Flange
(Narrow)
Female Flange
(Wide)
End View of Panel
A
Hood Panel
Hood Width
Figure 10.
Male
Female
DETAIL A
Hood Clip
Female
Male
NOTE: Use Hood Clips on Hood Panels 108" and wider.
DETAIL B
TWIN CITY FAN & BLOWER | WWW.TCF.COM
5959 Trenton Lane N | Minneapolis, MN 55442 | Phone: 763-551-7600 | Fax: 763-551-7601
3MWG08/13