Twin City Centrifugal Roof & Wall Exhausters - IM-4050 User Manual
Centrifugal powered roof & wall exhausters, Im-4050, Models
©2014 Twin City Fan Companies, Ltd.
Receiving, Inspection & Unpacking
General Installation
When the equipment is received all items should be carefully checked against the bill of lading to be sure all crates
and cartons have been received. Before accepting delivery, carefully inspect each carton or crate for visible shipping
damage. If any damage is noticed, the carrier should make the proper notation on the delivery receipt acknowledging
the damage. Make notations of all damage on all copies of the bill of lading and have all copies countersigned by
the delivering carrier. The carrier should also fill out a Carrier Inspection Report. The factory Traffic Department should
then be contacted. File claim for damage with the carrier. Physical damage to the unit after acceptance is not the
responsibility of Twin City Fan Companies, Ltd.
Unpack each carton or crate and verify that all required parts and proper quantities of each item have been received.
Refer to drawings for part descriptions. Report shortages or missing items to your local representative to arrange for
replacement parts.
Due to availability of carriers and truck space, it is not possible to guarantee that all items will be shipped together.
Verification of shipments must be limited to only those items on the bill of lading.
The unit nameplate must be checked to make sure the voltage agrees with the power supply available.
CAUTION: Sheet metal parts, screws, clips and similar items inherently have sharp edges, and it is necessary that the
installer and service personnel exercise caution.
The installation of this equipment shall be in accordance with the regulations of authorities having jurisdiction and all
applicable codes.
This equipment is to be installed by an experienced installation company and fully trained personnel.
The mechanical installation of the exhaust ventilator consists of making final connections between the unit and build-
ing services, duct connections.
Nomenclature
B CR U R - 120
D = Direct Drive
B = Belt Driven
CR = Centrifugal Roof Exhauster
CL = Centrifugal Low Profile
D = Downblast
U = Upblast
W = Wall Exhauster
H = Hooded
P = Penthouse (Louvered)
Fan Size
R = Restaurant
SH = Smoke & Heat
Models
DCLH, DCLP, DCRD, DCRU, DCRUR, DCRW, DCRWR
BCLH, BCLP, BCRD, BCRD-E, BCRU, BCRUR, BCRW, BCRWR, BCRUSH
Twin City Fan & Blower Catalogs 4050, 4105 and 4135 provide additional information on this equipment. These cata-
logs can be found at www.tcf.com or by contacting your local Twin City Fan & Blower sales representative.
IM-4050
August 2014
Centrifugal Powered
Roof & Wall Exhausters
INSTALLATION, OPERATION & MAINTENANCE MANUAL