beautypg.com

Twin City ATEX Fans - ES-309 User Manual

Twin City Fans

background image

Contents

Introduction..........................................................................1.

Personal.Protection.............................................................1.

Hazardous.Materials...........................................................1.

Installation

. . Shipping.and.Receiving.................................................1.

. . Handling..........................................................................1.

. . Unit.Storage....................................................................1

. . Foundations.and.Supporting.Structures

. . . -.Industrial.Fans........................................................1.

. . Fan.Installation.-.Assembled.or.Disassembled..........1.

. . Bearing.Installation.........................................................1

. . Shaft.Seal/Closing.Plate................................................1

. . Grouting...........................................................................1.

. . Drive.Mounting...............................................................1.

. . Flexible.Couplings..........................................................1.

. . Duct.Connections...........................................................1.

. . Guards.and.Enclosures.................................................2.

. . Electrical.Supply.and.Controls.....................................2.

. . Vibration..........................................................................2.

Maintenance.........................................................................2.

Fan.Operation

. . Proper.Use.and.Application.........................................2

. . Sound..............................................................................2

. . Operation.Checklist........................................................2

. . Troubleshooting.Guidelines............................................2

Introduction

This.manual.has.been.prepared.to.guide.users.of.fans.

designed. to. meet. the. requirements. of. the. European.

Unions.ATEX.(ATmosphères.EXplosifs).Directive..It.details.

the. measures. necessary. for. proper. installation,. opera-

tion.and.maintenance.procedures.and.is.in.accordance.

with.EN.14986..Personnel.operating.or.maintaining.this.

equipment.shall.be.trained.in.the.proper.procedures.for.

doing.so..

. This.manual.is.to.be.used.along.with.manual.ES-2-06.

“Installation,.Operation.and.Maintenance.Manual.–.Fans.

with. CE. Mark”.. This. addendum. for. ATEX. fans. identi-

fies. additional. considerations. beyond. ES-2-06. specific.

to.ATEX.fans..Guidelines.identified.in.ES-2-06.must.be.

followed.unless.otherwise.stated.here.

. ATEX.fans.are.supplied.for.safe.operation.in.the.con-

ditions.they.were.designed.for..However,.to.assure.safe.

operation,. the. fans. must. be. operated. within. the. limits.

identified. in. the. documentation. included. with. each. fan.

shipment.as.well.as.installed,.inspected.and.maintained.

as.indicated.in.ES-2-06.and.this.bulletin..Unless.autho-

rized. by. Twin. City. Fan. Companies,. Ltd.,. modifications.

must. not. be. made. to. the. fan.. Any. modification. per-

formed.would.void.the.warranty.and.ATEX.certification.

Personal Protection

See.ES-2-06.for.required.personal.protection.

Hazardous Materials

See.ES-2-06.for.hazardous.materials.considerations.

Installation

Shipping and Receiving

See.ES-2-06.for.shipping.and.receiving.requirements.

Handling

See.ES-2-06.for.handling.requirements.

Unit Storage

See.ES-2-06.for.storage.requirements.

Foundations and Supporting Structures
- Industrial Fans

See. ES-2-06. for. foundation. and. supporting. structure.

requirements.

Fan Installation - Factory Assembled or

Disassembled Units

See.ES-2-06.for.fan.installation.requirements.

Bearing Installation

See.ES-2-06.for.bearing.installation.requirements.

Shaft Seals / Closing Plate

Most. fans. supplied. by. Twin. City. Fan. Companies. for.

ATEX.applications.will.use.a.brass.closing.plate.to.mini-

mize.leakage.around.the.shaft...This.closing.plate.must.

be.aligned.to.give.approximately.the.same.clearance.at.

all. points. around. the. OD. of. the. shaft.. It. is. important.

that.the.alignment.of.this.plate.is.verified.before.start-

ing.the.fan.

. Seals.manufactured.by.others.must.be.installed,.oper-

ated,.and.maintained.per.the.manufacturer’s.instructions.

Grouting

See.ES-2-06.for.grouting.requirements.

Drive Mounting

See.maintenance.section.below.for.additional.consider-

ations.for.drives.on.ATEX.fans.

See.ES-2-06.for.additional.drive.mounting.requirements.

Flexible Couplings

See.ES-2-06.for.flexible.coupling.requirements.

Duct Connections

Fans.with.duct.connections.must.allow.for.inspection.of.

critical.clearances.between.rotating.and.stationary.parts.

and.must.allow.for.cleaning..Inlet.and.outlet.ducts.must.

have.sufficient.access.doors.to.allow.for.inspection.iden-

tified.in.this.bulletin.as.well.as.in.ES-2-06.

. The.layout.of.the.inlet.ducting.must.assure.that.the.

air.entering.the.fan.is.sufficiently.mixed.with.regards.to.

temperature.. Localized. hot. sections. of. the. air. stream.

could.become.a.hazard.if.they.are.at.a.higher.tempera-

ture.than.the.equipment.was.evaluated.for.

. Ducting.shall.be.so.arranged.that.the.fan.is.not.posi-

tioned.at.a.“low.point”.where.it.is.possible.for.foreign.

objects. or. liquid. to. lodge.. See. ES-2-06. for. additional.

duct.connection.requirements.

©2014.Twin.City.Fan.Companies,.Ltd.

ES-309

August 2014

ATEX Fans

INSTALLATION, OPERATION & MAINTENANCE MANUAL