beautypg.com

Microactivity, Half-­‐step – TruTrak Vizion 380-385 Operation Manual User Manual

Page 15

background image

 

Vizion  380/385  

15  

Rev  -­‐  Initial  

 

5.2.6. MICROACTIVITY  

 

Selectable  from  0  to  31.    This  setting  is  used  to  reduce  the  effects  

of  lost  motion  in  the  system.    Cable  operated  systems  will  need  to  use  

a  higher  value.    Most  pushrod  control  systems  can  use  a  value  of  0.    
Obtain   factory   assistance   before   making   large   adjustments   to   this  
setting.    The  vertical  axis  MICROACTIVITY  setup  screen  is  shown  in  
Figure  5.2.6a.  

 

 

Figure  5.2.6a  

5.2.7. HALF-­‐STEP?  

 

Selectable  between  N  and  Y.  This  setting  is  used  to  tune  out  an  

almost  imperceptible  pitch  oscillation  where  one  step  of  the  servo  is  
too   much   adjustment.     Set   to   Y   to   enable.     The   HALF   STEP?   setup  
screen  is  shown  in  Figure  5.2.7a.  

 

 

Figure  5.2.7a