beautypg.com

Para, P_46, P_10 – TriangleTube Mini Smart User Manual

Page 15: P_11, P_12

background image

IDWH Sensor Parameters

12

HOT WATER CAN SCALD!

Water temperatures over 125°F can cause
severe burns instantly or death from scalding

Children, disable and elderly are at highest
risk of being scald

Never leave them unattended in or near show-
er, bathtub or sink.

Never allow small children to use a hot water
faucet or draw their own bath.

If anyone using hot water in the building fits
the above description or if local codes or state
laws require specific water temperatures at
hot water faucet, it is recommended:

-

To install a thermostatic mixing valve at
this unit or at each water faucet.

-

To set the temperature setting for the low-
est temperature, which satisfies your hot
water needs.

Water drained from the system drain valves
may be extremely hot. To avoid injury:

-

Make sure all connections are tight

-

Direct water flow away from any person

DANGER

IDWH SENSOR PARAMETER

1. Once the access code number has been stored and

accepted in the control module, change the display
readout to “Parameter” mode by pressing MODE

until the display shows

PARA

.

2. Press STEP to enter the first parameter setting.

Continue pressing STEP until the display shows

P_46

.

By pressing STEP you will sequence through the

parameter settings as follows:

1140

,

2_01

,

3_01

,

4186

,

P_10

,

P_11

,

P_12

.....

P_46

. The display

readout will continue showing “

P

” followed by a 2

digit number that increases after each press of the
STEP button after the fourth parameter setting.

The parameter setting will continue for 21 different
parameter setting. By continuing to press the STEP
button, the display readout will rollover to the first
parameter setting.

3. When the display readout shows

P_46

, stop press-

ing the STEP button. Wait a second and the display
will flip over to the current setting of parameter 35 in
the right two digits of the display.

4. Press the + or - button to revise the setting until the

display shows

_12

.

5. Press the STORE button to save the change. The

display will flash once to indicate the control module
accepts the change.

NOTICE