PROGRAM ACCESS OF THE MCBA
CONTROL

The factory default setting for the PRESTIGE Control
Module to operate the IDWH is through an aquastat
control. The PRESTIGE Control Module must be pro-
grammed as described in the following instruction to
correctly operate the IDWH through the IDWH sensor.

To adjust the factory parameter settings of the PRES-
TIGE MCBA Control, the installer must enter into the
parameter menu of the control.

Do not attempt to revise any other control parameter
settings except those listed in this supplement.
Perform only those parameter revisions described in
this supplement. Failure to comply could result in
erratic or unreliable operation of the PRESTIGE
resulting in severe personal injury, death or sub-
stantial property damage.

For additional information on revising the PRES-
TIGE MCBA Control Module operational parameter
settings,

reference

the

PRESTIGE

Control

Supplement.

ACTIVATING THE ACCESS CODE

To enter the parameter listing of the MCBA control, the
installer must enter the activation code as follows:

1. Press and hold the MODE button

2. Continue holding the MODE and press STEP button

until

STBY

appears and hold both STEP and MODE

buttons for 2 to 3 seconds.

The display should read

CODE

3. Release the STEP and MODE buttons on the control

panel.

4. Press STEP once.

NOTICE

WARNING

NOTICE

The display should read

C_

XX

(XX should be

a random number from 00 to 99)

5. Press the + or - button to change the display num-

ber

C_

XX

to read

C_54

. Press and release the +

or - to change the display one number at a time.
Press and hold the + or - to rapidly change the dis-
play number.

6. When the display reads

C_54

press STORE to

save the activation code. The display

C_54

should

flash when the code is entered and saved.

After the activation code is entered press the MODE but-

ton until the display shows

PARA

. At this point the

installer can access the parameters required for applica-
tion.

Once in the parameter mode, press the STEP repeated-
ly to reach the appropriate parameter setting. The dis-
play should show the following sequence, as the STEP
button is press repeatedly:

Press STEP once-

1140

Press STEP x2 -

2_01

Press STEP x3 -

3_01

Press STEP x4 -

4186

Press STEP x5 -

P_10

Press STEP x6 -

P_11

Etc......

After Parameter 4 the display will continue to show P fol-
lowed by a two-digit number that increases with each
press of the STEP button.

The actual parameter values displayed on the
unit may vary depending on the application. The
parameter sequence will always occur in the
order shown.