beautypg.com

Cissell HF234 User Manual

Page 12

background image

12

3

Steam connection

With direct steam injection into the machine

1. Steam pipe

2. Steam cut-off valve 3/8"

3. Pipe coupling 3/8"

4. Steam fi lter 3/8"

5. Magnetic steam valve 3/8"

6. Curve MF 3/8"

7. Steam hose with appropriate pipe coupling 3/8"

The manufacturer is not responsible for damage or accidents
caused by not following the installation instructions!

Added parts for steam heating with heat exchanger

3. Double pipe coupling 1/2"

9. Condensation accumulator with fi lter 1/2"

10. Conical coupling MM 1/2"
11. Single window 1/2"
12. One-way valve 1/2"

M = inner wire, F = outer wire

Machines with steam heating must have a steam valve between the steam
installation and the machine.