Toa C-BC511A User Manual
Page 4
Surface treated steel plate, black, paint
132 (W) x 30 (H) x 70 (D) mm (5.2 (W) x 1.2 (H) x 2.8 (D) inch)
160 g (0.35 lb)
C-CC514, C-CC564, C-CC574, N-CC2564
C-BC511C, C-BC511C-S
Finish
Dimensions
Weight
Applicable camera
Applicable cover
Note: The design and specifications are subject to change without notice for improvement.
2
4
5
1
3
Safety wire (accessory)
Anchor bolt
Ceiling
Safety wire
(supplied with the
combination camera)
Celing Mounting
Bracket
C-BC511A
Base unit
Combination
Camera (optional)
C-CC514
C-CC564
C-CC574
Network
Combination Dome
Camera (optional)
N-CC2564
Camera unit
Celing Mounting
Cover (optional)
C-BC511C
C-BC511C-S
1. Attach the ceiling mounting bracket to
the ceiling mounting anchor bolt
installed into the upper ceiling.
2. Attach the base unit to the ceiling
mounting bracket.
Note
Use the supplied camera mounting
screws when attaching the base unit to
the ceiling mounting bracket.
3. Connect cables and attach the camera
unit to the base unit.
4. Align the ceiling mounting cover's
positioning mark with that on the base
unit.
5. Rotate the ceiling mounting cover
clockwise until it locks into place.
Be sure to carefully read the installation
manual supplied with the camera.
[ Main body mounting view ]
• Accessories
Camera mounting screw (machine screw M4 x 60) ................. 4
Safety wire ................................................................................ 1
Pattern paper ............................................................................ 1
Space between suspe-
nded ceiling panel and
upper ceiling 100 mm
(3.9 inch) or more
Ceiling panel
40 mm (1.6 inch)
or less
140 – 145 mm
(5.5 – 5.7 inch)
Note:
When routing the cables from the ceiling if the unit is used
in conjunction with the N-CC2564, the ceiling panel must be
9 – 40 mm (0.4 – 1.6 inch) in thickness.
[ Installation dimensional diagram ]
4. INSTALLATION
5. SPECIFICATIONS
133-05-397-7A