Connect the remote control output to the PP-025B Pre-amplifier Panel's line input jack. Use the twin shielded
cable for connection.
Priority setting
First-in-first-out priority: Connect the First-in-first-out terminal of one remote control unit to the same terminal
of another. Up to five units can be connected for the FIFO priority function.
Of the two remote control units, the unit making an announcement first takes
precedence. While one unit is in use, other remote control unit cannot be used.
Individual unit priority: Connect the Individual unit priority/sending terminal of the remote control unit given
higher priority to the Individual unit priority/receiving terminal of the unit with lower
priority. Up to five units can be connected.
In this example, Remote Control Unit 1 takes precedence over Remote Control
Unit 2. While Unit 1 is making broadcast, Unit 2 cannot be used. Conversely, while
Unit 2 is making broadcast, Unit 1 can be used.
When not setting the priority order
When using only one RM-1100 unit or when using multiple units but not assigning priority, do not connect the
First-in-first-out terminal or Individual unit priority terminal.
Cable type vs. cable length
H
C
E
Cable length
Under 400 m
Under 800 m
Under 1200 m
Power/control cable
Over ø0.65 mm
Over ø0.9 mm
Over ø1.2 mm
Shielded cable
Over ø0.26 mm
Over ø0.35 mm
Over ø0.5 mm
Remote Control Unit 1
Remote Control Unit 2
ANN ON
RM
1ST-IN-1ST-OUT
R
T
PRIORITY
ALL-ZONE
CHIME
COM
+
-
24 VDC
POWER
REMOTE
OUTPUT
H
C
E
ANN ON
RM
1ST-IN-1ST-OUT
R
T
PRIORITY
ALL-ZONE
CHIME
COM
+
-
24 VDC
POWER
REMOTE
OUTPUT
H
C
E
Remote Control Unit 1
Remote Control Unit 2
ANN ON
RM
1ST-IN-1ST-OUT
R
T
PRIORITY
ALL-ZONE
CHIME
COM
+
-
24 VDC
POWER
REMOTE
OUTPUT
H
C
E
ANN ON
RM
1ST-IN-1ST-OUT
R
T
PRIORITY
ALL-ZONE
CHIME
COM
+
-
24 VDC
POWER
REMOTE
OUTPUT
H
C
E