Block diagram, Specifications, Block diagram 16. specifications – Toa DP-SP3 User Manual
Page 22
22
INPUT 1
+4 dB*
Analog
Digital
Analog
A/D
SIGNAL
RED
GREEN
L
BUS
R
FILTER
×10
INPUT 2
+4 dB*
EBA
PAD
A/D
SIGNAL
RED
GREEN
FILTER
×10
EBA
CPU CONTROL
DELAY
MUTE
D/A
FILTER
×12
LA
SIGNAL
RED
GREEN
OUTPUT 1
+4 dB*
DELAY
MUTE
D/A
FILTER
×12
LA
SIGNAL
RED
GREEN
OUTPUT 2
+4 dB*
DELAY
MUTE
D/A
FILTER
×12
LA
SIGNAL
RED
GREEN
OUTPUT 3
+4 dB*
DELAY
MUTE
D/A
FILTER
×12
LA
SIGNAL
RED
GREEN
OUTPUT 4
+4 dB*
DELAY
MUTE
D/A
FILTER
×12
LA
SIGNAL
RED
GREEN
OUTPUT 5
+4 dB*
DELAY
COMP
COMP
COMP
COMP
COMP
MUTE
D/A
FILTER
×12
LA
SIGNAL
RED
GREEN
OUTPUT 6
+4 dB*
*
0 dB = 0.775 V
ON
(–14 dB)
OFF
PAD
ON
(–14 dB)
OFF
COMP
15. BLOCK DIAGRAM
16. SPECIFICATIONS
Version
CE/CE-GB
CE-AU
CU
Power Source
220−240 V AC, 50/60 Hz
220−240 V AC, 50 Hz
100−120 V AC, 60 Hz
Power Consumption
25 W
Frequency Response
20 Hz − 20 kHz, ±1 dB
Sampling Frequency
96 kHz
Dynamic Range
110 dB or more
Distortion
0.03 % or less, 1 kHz, +4 dB* input/output, 20 Hz − 20 kHz BPF
Crosstalk
−80 dB or less, 1 kHz
Input
2 channels, +4 dB* (max. +24 dB*), 10 kΩ,
electronically-balanced, removable terminal block (3P)
Output
6 channels, +4 dB* (max. +24 dB*), applicable load 600 Ω or more,
electronically-balanced, removable terminal block (3P)
AD Converter
24 bits
* 0 dB = 0.775 V