Note: Binary control example by way of the 3P terminal
Detects the
leading edge.
Max 50 ms
200 ms
Undefined
Detects the
trailing edge.
Max 50 ms
200 ms
Undefined
Detects the
leading edge.
Max 50 ms
200 ms
Preset memory
switches.
Terminal 1
Terminal 2
Terminal 3
[Binary mode]
The following tables show the relationship between the
statuses to be given to the terminals and Preset memories
to be recalled.
Selecting 2 Preset memories using the terminal 4
Preset memory number Terminal 4
1
Open
2
Closed
Selecting 4 Preset memories using the terminals 3 and 4
Preset memory number Terminal 3 Terminal 4
1
Open
Open
2
Open
Closed
3
Closed
Open
4
Closed
Closed
Selecting 8 Preset memories using the terminals 2, 3, and 4
Preset memory number Terminal 2 Terminal 3 Terminal 4
1
Open
Open
Open
2
Open
Open
Closed
3
Open
Closed
Open
4
Open
Closed
Closed
5
Closed
Open
Open
6
Closed
Open
Closed
7
Closed
Closed
Open
8
Closed
Closed
Closed
Selecting 16 Preset memories using the terminals 1, 2, 3, and 4
Preset memory number Terminal 1 Terminal 2 Terminal 3 Terminal 4
1
Open
Open
Open
Open
2
Open
Open
Open
Closed
3
Open
Open
Closed
Open
4
Open
Open
Closed
Closed
5
Open
Closed
Open
Open
6
Open
Closed
Open
Closed
7
Open
Closed
Closed
Open
8
Open
Closed
Closed
Closed
9
Closed
Open
Open
Open
1 0
Closed
Open
Open
Closed
11
Closed
Open
Closed
Open
1 2
Closed
Open
Closed
Closed
1 3
Closed
Closed
Open
Open
1 4
Closed
Closed
Open
Closed
1 5
Closed
Closed
Closed
Open
1 6
Closed
Closed
Closed
Closed
To switch the Preset memory, maintain the given state for 250 ms or more after placing each terminal in the
state corresponding to the Preset memory to be recalled.
Maintain the terminal state as it is until changing the Preset memory next time.