Preset number indication function, Control method using the contact input terminals, Preset memory recall – Toa DP-SP3 User Manual
Page 14: Control method using, The contact input terminals
![background image](/manuals/714211/14/background.png)
14
Lights
(While the Preset Memory 1 is being recalled)
DP-SP3
9. PRESET NUMBER INDICATION FUNCTION
Using the supplied DP-SP3 PC Software, various setting data can be stored on the DP-SP3, which can be
recalled.
The saved setting data is referred to as “Preset memory.”
The supplied DP-SP3 PC Software allows up to 16 patterns of the Preset memories to be stored or recalled.
For the store and recall methods, read the separate DP-SP3 Software Instructions.
While one of the Preset memories 1 through 4 is being
recalled, its corresponding numbered Preset indicator of
the DP-SP3 lights.
Tip
When all 4 Preset indicators are unlit, the DP-SP3 is
placed in one of the following statuses.
• Preset memories 5 through 16 are being recalled.
• The DP-SP3 is activating in Resume function ON state.
• Setting is changed after activating the DP-SP3.
Detects the
leading edge.
Max. 50 ms
200 ms
Preset memory
switches.
Detects the
leading edge.
Max. 50 ms
200 ms
Preset memory
switches.
10. CONTROL METHOD USING THE CONTACT INPUT TERMINALS
This chapter will describe control method of the contact input terminals to recall the Preset memory, adjust the
volume level of output channels, and control the Mute ON/OFF by external equipment.
Note: For the settings of each individual function, read the separate DP-SP3 Software Instructions.
10.1. Preset Memory Recall
Up to 4 Preset memories in Direct mode and up to 16 Preset memories in Binary mode can be controlled.
[Direct mode]
Either (A) or (B) below can be used for the control method.
In either case, Preset memory switches 250 ms or more after the contact inputs have been closed.
(A) Maintaining the contact terminal closed after
the Preset memory has been switched.
(B) Opening the contact terminal after the Preset
memory has been switched.
Tip
Use the DP-SP3 PC Software to assign which terminals 1 through 4 to which Preset memory.
Read the separate DP-SP3 Software instructions.