8.5.5. Shift switch setting
Use SW201's switches No. 1 - No. 4 and SW202's switch No. 3 to set the shift switch. The shift switch setting
is necessary for the system which controls broadcast in multiple buildings from a central control room. The
above switches are all set for OFF at the factory.
Shown below are the installation example and shift switch settings required for that installation.
[Installation example]
Building A
Building B
Main rack
(50 zones)
RM
(20 zones)
RM
Building C
(40 zones)
RM
Note: [RM] represents a remote control unit.
Main rack (system)
EP-0510
EP-029-10
EP-029-20
EP-029-10
EP-029
Address No.
0
1
2
For Building A
EP-029-10
EP-029-10
3
4
For Building B
EP-029-10
EP-029-20
EP-029-10
5
6
7
For Building C
Building A remote control unit
EP-059R
EP-029-10
EP-029-20
EP-029-10
EP-029
Address No.
0
1
2
SW201
SW202
Building B remote control unit
EP-059R
EP-029-10
EP-029
Address No.
4
SW201
SW202
Building C remote control unit
EP-059R
EP-029-20
EP-029-10
EP-029
Address No.
6
7
SW201
SW202
EP-059R
Address No.: 0
EP-059R
Address No.: 1
EP-059R
Address No.: 2
EP-059R Address No.: 0
(SW201 No. 6 - No. 8)
EP-029 shift switch: Invalid (OFF)
(SW202 No. 3)
No. of EP-029 units: 3
(SW202 No. 4 - No. 8)
EP-059R Address No.: 1
(SW201 No. 6 - No. 8)
EP-029 shift switch: Valid (ON)
(SW202 No. 3)
EP-029 shift switch (No.): 3
(SW201 No. 1 - No.4)
No. of EP-029 units: 1
(SW202 No. 4 - No. 8)
EP-059R Address No.: 2
(SW201 No. 6 - No. 8)
EP-029 shift switch: Valid (ON)
(SW202 No. 3)
EP-029 shift switch (No.): 5
(SW201 No. 1 - No.4)
No. of EP-029 units: 2
(SW202 No. 4 - No. 8)