Toa FS-970 SERIES User Manual
Page 39

39
• Evacuation Announcement interval (SW4-4 through SW4-8)
Time intervals can be set for 30 seconds to 15 minutes 30 seconds in 30 seconds units.
• All-zone announcement interval (SW2-3 through SW2-8)
Time intervals can be set for "OFF", "0 second" or "30 seconds to 15 minutes 30 seconds" in 30 seconds
units.
• Warning Announcement (SW3-2 through SW3-8)
Set "repeat yes or no", "number of repeats", "repeat intervals", and "repeat mode" for the Warning
Announcement.
SW4
ON
OFF
4
0
8 minutes
5
0
4 minutes
6
0
2 minutes
7
0
1 minute
8
0
30 seconds
SW4
Evacuation Announcement interval
ON
1 2 3 4 5 6 7 8
SW2
ON
OFF
3
Off
On
4
0
8 minutes
5
0
4 minutes
6
0
2 minutes
7
0
1 minute
8
0
30 seconds
SW2
All-zone announcement interval
ON
1 2 3 4 5 6 7 8
SW3
ON
OFF
2
Termination
Resumption
SW3
Repeat mode
No. of repeats
Repeat interval
Repetition
ON
1 2 3 4 5 6 7 8
3
+0
+2
4
+0
+1
5
No
Yes
6
0 minute
1 minute
7
0 second
30 seconds
8
0 second
15 seconds
Memo
• "Resumption": Warning Announcement interrupted by a PA microphone announcement is resumed after
microphone announcement completion.
• "Termination": Warning Announcement is terminated when a PA microphone announcement is made. (It is
not resumed even when the microphone announcement is completed.)
• Number of repeats: Warning Announcement is repeated twice when the SW3-3 and SW3-4 switches are
both set to OFF. If, for example, the SW3-3 switch (+2) is set to ON, the number of repeats increases by
two, causing the Warning Announcement to be repeated four times.