Approved for outdoor installation on wood flooring or on class A,
B or C roof covering materials.

Before performing service or maintenance operations on
system, turn off main power to unit and install lock-out tag.
Turn off accessory heater power switch if applicable. Elec-
trical shock could cause severe injury or death.

Puron® (R-410A) systems operate at higher pressures than
standard R-22 systems. Do not use R-22 service equipment or
components on Puron® (R-410A) equipment. Ensure service
equipment is rated for Puron® (R-410A)

INTRODUCTION

NOTE: The minimum outdoor cooling operating temperature for
units using this ICM motor option is 55°F. To operate in cooling
at lower ambients the Motor Master™ II low ambient kit is
required.

These instructions cover the installation of a Carrier Small
Packaged Product with ICM motor-factory installed option
(FIOP). This option can be selected as a FIOP on gas
heating/electric cooling (48GP), dual fuel–electric heat pump with
gas heat back-up (48JZ), electric cooling (50GL) or electric heat
pump (50JZ) units with Puron®.

RECEIVING AND INSTALLATION

Refer to unit Installation Instructions.

ICM FIOP PRE-START-UP

Step 1—Electrical Connections

CONTROL VOLTAGE CONNECTIONS

NOTE: Do not use any type of power-stealing thermostat, with-
out connecting the C (Common) terminal. Failure to follow this
note could result in unit control problems.

Use no. 18 American Wire Gage (AWG) color-coded, insulated
(35 C minimum) wires to make the control voltage connections
between the thermostat and the unit. If the thermostat is located
more than 100 ft from the unit (as measured along the control
voltage wires), use no. 16 AWG color-coded, insulated (35 C
minimum) wires.

STANDARD CONNECTION

Remove knockout hole located in the heat section panel adjacent to
the service access panel (See unit installation package). Remove
the rubber grommet from the installer’s packet (included with unit)
and install grommet in the knockout opening. Provide a drip loop
before running wire through panel. Run the low-voltage leads from
the thermostat, through the inlet hole, and into unit low-voltage
splice box. Locate 18-gage wires leaving control box. These
low-voltage connection leads can be identified by colors (See Fig.
2, 3, 4 or 5). Ensure the leads are long enough to be routed into the
low-voltage splice box (located below right side of control box).
Route leads through hole in bottom of control box and make
low-voltage connections (See Fig. 2, 3, 4 or 5). Secure all cut
wires, so that they do not interfere with operation of unit.

SPECIAL PROCEDURES FOR 208–V OPERATION

Make sure that the power supply to the unit is switched OFF
before making any wiring changes. With disconnect switch
open, move yellow wire from transformer (3/16 in.) terminal
marked 230 to terminal marked 200. This retaps transformer
to primary voltage of 208-v. Electrical shock could cause
serious injury or death.

EASY SELECT™—48GP

EASY SELECT™ CONFIGURATION TAPS FOR 48GP
Easy Select™ taps are used by the installer to configure a system.

Fig. 2—48GP High- and Control-Voltage

Connections

C01026

POWER
SUPPLY

FIELD-SUPPLIED
FUSED DISCONNECT

HIGH VOLTAGE
POWER LEADS
(SEE UNIT WIRING
LABEL)

GND

CONTROL BOX

SPLICE BOX

LOW-VOLTAGE
POWER LEADS
(SEE UNIT
WIRING LABEL)

YEL(Y)

GRN(G)

RED(R)

BRN(C)

THERMOSTAT
(TYPICAL)

LEGEND

Field Control-Voltage Wiring
Field High-Voltage Wiring

BLK(DH)

DHUM

Y

G

R

C

W1

WHI(W1)

Fig. 3—48JZ High- and Control-Voltage

Connections

C01107

POWER
SUPPLY

FIELD-SUPPLIED
FUSED DISCONNECT

HIGH VOLTAGE
POWER LEADS
(SEE UNIT WIRING
LABEL)

GND

CONTROL BOX

SPLICE BOX

LOW-VOLTAGE
POWER LEADS
(SEE UNIT
WIRING LABEL)

THERMOSTAT

(THERMIDISTAT ™ )

G

R

C

YEL(Y)

GRN(G)

RED(R)

BRN(C)

ORN(O)

W/W1

WHT(W1)

DHUM

BLK (DH)

FIELD CONTROL - VOLTAGE WIRING
FIELD HIGH - VOLTAGE WIRING

Y/Y2

O/W2

2