7. Pump

autocalibration

Function

Display

Possible actions

Comments

2.2 Injection
pump
calibration

Inj . pump

6.00

↓ to modify value

Pro to validate value (2)

This is the complete
pump calibration (all
heads together.
Units are pulses/ml.

CLR to start Autocalibration

Average value is 3.00 per
head for a piston pump.

2.2.1

St ar t

aut ocal

CLR to exit Autocalibration


Push on the CAL switch on the pump to
start the calibration.
Collect the pumped volume.
Keep the CAL switch pushed until
calibration is finished

Pump must be ready to
inject (tubes filled)

2.2.2

St ar t

235 p

Display shows the counted pulses from
the pump.

Release the CAL switch
when enough pulses
have been counted.

2.2.3

inj . vol

0.000 l

↑ ↓ to set the pumped volume

Pro to validate

Release the CAL switch
when enough pulses
have been counted.

8. Prime

autocalibration

Function

Display

Possible actions

Comments

↓ to modify value

This is the volume that
must be pumped to prime
the system.

3.1 Prime
calibration

Pr ime

2.000 l

Pro to validate value

CLR to start Autocalibration


Push on the CAL switch on the pump to
start the calibration.

2.2.1

St ar t

aut ocal

Keep the CAL switch pushed until
calibration is finished

Display will show injected volume

2.2.1

pr iming

0.000 l

Release the CAL switch when system
has been primed

Pro to validate

026-UK V1.01

18/05/2006