6. Program

Function

Display

Possible actions

Comments

Access / Exit

Push Pro for 3 seconds

Master must be off

1. Carrier
flowmeter

Car . f l ow

set up

↓ to select another step

Pro to enter carrier flowmeter

calibration (1.1)

Push Pro for 3 seconds to escape
program

1.1

Car . f l ow

150 p/ l

↑ ↓ to modify value

Pro to validate value

Main carrier flowmeter
calibration in pulses/lt

2. Injection
pump

Inj . pump

set up

↑ ↓ to select another step

Pro to enter calibration (2.1)


Push Pro for 3 seconds to escape
program

2.1 Injection
pump type

Inj . pump

Pist on 2

↓ to modify value

Pro to validate value (2.2)

CLR to escape (2)

Choices are :
Peristaltic
Piston 1 (head)
Piston 2 (heads)
Piston 3 (heads)
Piston 4 (heads)

2.2 Injection
pump
calibration

↓ to modify value

This is the complete
pump calibration (all
heads together.

Inj . pump

6.00

Pro to validate value (2)

CLR to start Autocalibration (see ch. 7)

Units are pulses/ml.
Average value is 3.00 per
head for a piston pump.

3. Prime
calibration

pr ime

set up

↑ to select another step

Pro to enter calibration (3.1)


Push Pro for 3 seconds to escape
program

3.1

Pr ime

2.000 l

↓ to modify value

Pro to validate value

CLR to start Autocalibration (see ch. 8)

This is the volume that
must be pumped to prime
the system.

026-UK V1.01

18/05/2006

Page 6 of 8