beautypg.com

Citizen Systems Citizen PPU PPU-700 User Manual

Page 39

background image

— 36 —

MSW2

Switch No.

Function

0 (OFF)

1 (ON)

Factory
Setting

2-1

Reserved

Fixed

ON

2-2

Auto-cutter

Disabled

Enabled

ON

2-3

Buffering printing

Disabled

Enabled

ON

2-4

Full digit printing

PPU

EPSON

ON

2-5

Treatment after PE recovery

Print next line

Print top

OFF

when cover is closed

2-6

Reserved

Fixed

OFF

2-7

Reserved

Fixed

OFF

2-8

NPE enabled/disabled

Enabled

Disabled

OFF

MSW3

Switch No.

Function

0 (OFF)

1 (ON)

Factory
Setting

3-1

Recovery from cutter

Enabled

Disabled

OFF

error with FEED switch

3-2

Cover open error at

Cover closed

Command

OFF

selection of recoverable error

3-3

Selects parallel #31 pin

Reset

Ignored

OFF

RESET signal

3-4

Selects paper

Thermal paper

Black marked paper

OFF

3-5

Reserved

Fixed

OFF

3-6

Reserved

Fixed

OFF

3-7

Selects mode

PPU mode

L90 mode

OFF

3-8

Printer cover open

Automatic recovery error

Recoverable error

OFF

during printing

MSW4

Switch No.

Function

0 (OFF)

1 (ON)

Factory
Setting

4-1

Reserved

Fixed

OFF

4-2

Reserved

Fixed

OFF

4-3

Setting first print

Set

Not set

OFF

position at power on

4-4

Collecting operation

Disabled

Enabled

OFF

4-5

Direction of collection

Backward

Forward

OFF

4-6

Paper ejection

Normal ejection

Direct ejection

OFF

4-7

Presenter operation

Operation disabled

Operation enabled

OFF

with paper

4-8

Reserved

Fixed

OFF