Citizen Systems Citizen PPU PPU-700 User Manual
Page 39

— 36 —
MSW2
Switch No.
Function
0 (OFF)
1 (ON)
Factory
Setting
2-1
Reserved
—
Fixed
ON
2-2
Auto-cutter
Disabled
Enabled
ON
2-3
Buffering printing
Disabled
Enabled
ON
2-4
Full digit printing
PPU
EPSON
ON
2-5
Treatment after PE recovery
Print next line
Print top
OFF
when cover is closed
2-6
Reserved
Fixed
—
OFF
2-7
Reserved
Fixed
—
OFF
2-8
NPE enabled/disabled
Enabled
Disabled
OFF
MSW3
Switch No.
Function
0 (OFF)
1 (ON)
Factory
Setting
3-1
Recovery from cutter
Enabled
Disabled
OFF
error with FEED switch
3-2
Cover open error at
Cover closed
Command
OFF
selection of recoverable error
3-3
Selects parallel #31 pin
Reset
Ignored
OFF
RESET signal
3-4
Selects paper
Thermal paper
Black marked paper
OFF
3-5
Reserved
Fixed
—
OFF
3-6
Reserved
Fixed
—
OFF
3-7
Selects mode
PPU mode
L90 mode
OFF
3-8
Printer cover open
Automatic recovery error
Recoverable error
OFF
during printing
MSW4
Switch No.
Function
0 (OFF)
1 (ON)
Factory
Setting
4-1
Reserved
Fixed
—
OFF
4-2
Reserved
Fixed
—
OFF
4-3
Setting first print
Set
Not set
OFF
position at power on
4-4
Collecting operation
Disabled
Enabled
OFF
4-5
Direction of collection
Backward
Forward
OFF
4-6
Paper ejection
Normal ejection
Direct ejection
OFF
4-7
Presenter operation
Operation disabled
Operation enabled
OFF
with paper
4-8
Reserved
Fixed
—
OFF