to be understated and will affect decompression calculations. If you want to adjust the
computer to provide more conservative calculations, use the personal adjustment
feature to affect decompression calculations, or reduce the PO

2

setting to affect oxygen

exposure according to the entered O

2

% and PO

2

values. Calculations based on nitrox

use result in longer no-decompression times and shallower maximum depths than
diving with air.

NOTE

As a safety precaution, the oxygen calculations in the dive com-
puter are made with an oxygen percentage of 1% + set O

2

%.

When the dive computer is set in NITROX mode, the Dive Planning mode calculates
using the O

2

% and PO

2

values that are currently in the computer.

To set the nitrox mixes, refer to Section 5.8.1. Setting the nitrox values .

Default nitrox settings
In the NITROX mode, the Suunto D4i allows you to set a nitrox mix containing 21–50%
oxygen.
In the NITROX mode, the default setting is standard air (21% O

2

). It remains in this

setting until the O

2

% is adjusted to any other percentage of oxygen (22%–50%). The

default setting for maximum oxygen partial pressure is 1.4 bar, however you are able
to set it in the range of 0.5–1.6 bar.

6.2.2. Oxygen displays
When the NITROX mode is activated, the display will show the information in the figure
below. In the NITROX mode, the maximum operational depth is calculated based on
set O

2

% and PO

2

values.