Diving in nitrox mode (dive nitrox), Before diving in the nitrox mode – SUUNTO D4i User Manual
Page 78
DECOMPRESSION DIVE, ABOVE CEILING.
NOTE DOWNWARD POINTING ARROW, ER WARNING
AND ALARM. YOU SHOULD IMMEDIATELY (WITHIN
3 MINUTES) DESCEND TO OR BELOW CEILING.
In addition, an Error warning (Er) reminds you that you have only three (3) minutes to
correct the situation. You must immediately descend to, or below, the ceiling.
If you continue to violate the decompression, the dive computer will go into a permanent
Error Mode. In this mode, the instrument can only be used as a depth gauge and timer.
You must not dive again for at least 48 hours (refer to Section 5.6. Error conditions).
6.2. Diving in NITROX mode (DIVE Nitrox)
The NITROX mode (DIVE Nitrox) is the second dive mode available in Suunto D4i
and is used when using oxygen-enriched gas mixtures.
6.2.1. Before diving in the NITROX mode
If set to the NITROX mode, the correct oxygen percentage of the gas in your cylinder
must always be entered into the computer to ensure correct nitrogen and oxygen
calculations. The dive computer adjusts its mathematical nitrogen and oxygen calcu-
lation models accordingly. The dive computer will not accept fractional percentage
values of oxygen concentration. Do not round up fractional percentages. For example,
31.8% oxygen should be entered as 31%. Rounding up will cause nitrogen percentages
79