beautypg.com

Appendix, Print line output data items – Sonics GXT User Manual

Page 34

background image

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

I N S T R U C T I O N M A N U A L • M O D E L G X T P O W E R S U P P LY

32

Go To Top Of Document

A P P E N D I X

Item 1: Using the first line of the sample listing above, item 1 is the

“Customer Resettable Counter” (CRC). It is located at position 1 through

position 6 so the value of 005647 indicates that the last cycle was weld

number 5647 since the last time it was reset to 0 (see page 18).

005647

00.48 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----

Item 2: The second item sent is the actual weld time from the last cycle –

the time that the ultrasonic generator was running. So 00.48 means that the

generator was ON for .48 seconds. If the weld cycle finished its programmed

weld time, then the following “sec” would have been transmitted as upper

case letters or “SEC.” The “sec” is lower case so the weld cycle was

terminated through some other parameter. The time data is located at

positions 8 through 12 and includes the “.” at position 10. The “sec” label is

located at position 14 through position 16. Space characters are located at

positions 7, 13 and 17.

005647

00.48 sec

0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----

Item 3: Next is the distance data. Distance controls are not available on

Model GXT, so the Distance data will always appear as 0.000 in or 00.00

mm.

005647 00.48 sec

0.000 in

000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----

Item 4: Next is the energy data. Energy controls are not available on Model

GXT, so the Energy data will always appear as 000000J.

005647 00.48 sec 0.025 in

000000 J

045 %Pmax Alarms T:-- D:-- E:-- J06 -----

Item 5: The maximum percent power number is next in line at positions 36

through 38 with a space at 39. This number is the maximum percent of

power developed during the last weld cycle. The label “%Pmax” does not

change case as the control items can for time, distance (Model GXL only)

and energy. It is not a control parameter, just a label for text readability.

005647 00.48 sec 0.025 in 000130 J

045 %Pmax

Alarms T:-- D:-- E:-- J06 -----

PRINT LINE OUTPUT DATA ITEMS