Appendix, Print line output data items – Sonics GXT User Manual
Page 34
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
I N S T R U C T I O N M A N U A L • M O D E L G X T P O W E R S U P P LY
32
A P P E N D I X
Item 1: Using the first line of the sample listing above, item 1 is the
“Customer Resettable Counter” (CRC). It is located at position 1 through
position 6 so the value of 005647 indicates that the last cycle was weld
number 5647 since the last time it was reset to 0 (see page 18).
005647
00.48 sec 0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
Item 2: The second item sent is the actual weld time from the last cycle –
the time that the ultrasonic generator was running. So 00.48 means that the
generator was ON for .48 seconds. If the weld cycle finished its programmed
weld time, then the following “sec” would have been transmitted as upper
case letters or “SEC.” The “sec” is lower case so the weld cycle was
terminated through some other parameter. The time data is located at
positions 8 through 12 and includes the “.” at position 10. The “sec” label is
located at position 14 through position 16. Space characters are located at
positions 7, 13 and 17.
005647
00.48 sec
0.025 in 000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
Item 3: Next is the distance data. Distance controls are not available on
Model GXT, so the Distance data will always appear as 0.000 in or 00.00
mm.
005647 00.48 sec
0.000 in
000130 J 045 %Pmax Alarms T:-- D:-- E:-- J06 -----
Item 4: Next is the energy data. Energy controls are not available on Model
GXT, so the Energy data will always appear as 000000J.
005647 00.48 sec 0.025 in
000000 J
045 %Pmax Alarms T:-- D:-- E:-- J06 -----
Item 5: The maximum percent power number is next in line at positions 36
through 38 with a space at 39. This number is the maximum percent of
power developed during the last weld cycle. The label “%Pmax” does not
change case as the control items can for time, distance (Model GXL only)
and energy. It is not a control parameter, just a label for text readability.
005647 00.48 sec 0.025 in 000130 J
045 %Pmax
Alarms T:-- D:-- E:-- J06 -----
PRINT LINE OUTPUT DATA ITEMS