beautypg.com

Installation, Electrical power, Air supply – Sonics 4096 Actuator User Manual

Page 10: Setting up, Key components, Electrical power air supply, Setting up key components

background image

I N S T R U C T I O N M A N U A L • M O D E L 4 0 9 5 / 4 0 9 6

9

• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •

I N S T A L L A T I O N

ELECTRICAL POWER

The press is powered by the power supply. Consult your power supply

instruction manual to determine power specifications.

AIR SUPPLY

The press requires a source of dry, filtered (5 micron), oil-free, compressed

air capable of supplying a constant line pressure of 85 psig. (586 kPa / 6 bar)

at a minimum capacity of 2 CFM.

SETTING UP

The press should be installed in a clear, uncluttered location that is free from

excessive dirt, dust, corrosive fumes, and temperature and humidity

extremes. The selected installation site should be near the electrical power

and air supply sources and away from any equipment that generates

abnormally high electrical transients. Observe the following additional

instructions when installing the press:

a. The press should be placed on a sturdy, level table or bench capable of

supporting a minimum of 500 pounds (227 kg).

b. Allow at least 6 inches (152.4mm) at the rear of the press for cable

connections.

KEY COMPONENTS

Do not connect the press

to an air source supplied

by a compressor lubricated

with synthetic oils or oils

containing phosphate

esters or chlorinated

hydrocarbons. This type of

lubricant may cause the air

filter to malfunction, and

the plastic bowl to rupture.

NOTE: If the power supply

is to be run continuously,

air cooling of the converter

and horn is required. Use

clean, dry compressed air

filtered down to 5 microns

(supplied to converter

fitting).

AIR
FILTER/REGULATOR
ASSEMBLY

CONVERTER HOUSING
with converter, booster &
horn (stack) assembly

PALM ACTIVATION
BUTTONS

CONVERTER
HOUSING DOOR

PART HOLDING
FIXTURE

EMERGENCY STOP
BUTTON

Go To Top Of Document

This manual is related to the following products: