Operating procedures, Control panel – Sonics 1596 Actuator User Manual
Page 12
• • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • • •
I N S T R U C T I O N M A N U A L • M O D E L 1 5 9 5 / 1 5 9 6
11
O P E R A T I N G P R O C E D U R E S
CONTROL PANEL
Located to the right of the converter housing is a control panel with the
following features:
1. Blue HEAD POSITION buttons (labeled “RAISE” and “LOWER”) which
move the head up or down on the column when depressed.
2. Black and red SPEED CONTROL knobs which allow regulation of the
speed at which the horn descends and returns (stroke speed).
These controls are factory adjusted for average operating conditions. When
minor adjustments are necessary, be sure to adjust in small degrees.
The upper knob, labeled “UP,” controls the return speed – turn it clockwise
to slow the speed, counterclockwise to increase speed.
The lower knob, labeled “DOWN,” controls the extend speed – turn it
clockwise to slow the speed, counterclockwise to increase the speed.
3. Black PRESSURE REGULATORS with corresponding gauges that
allow regulation of the pressure with which the horn contacts the part and
returns to the home position. Pull the knobs to make adjustments, and then
push in to lock settings when desired pressure is displayed. Once pulled,
turning the knobs clockwise increases pressure, and turning them
counterclockwise decreases pressure.
4. The HORN DOWN key switch which when turned clockwise moves the
converter housing to the extended position (this action does not cause
ultrasonics to be activated).
❶
❷
❹
❸
Go To Top Of Document