beautypg.com

Scientech S310 Vector User Manual

Page 2

background image

2

Thank you for choosing a Scientech laser power and energy meter. Scientech, an ISO 9001 registered
company, and our employees are pleased to provide you with a product designed for years of reliable service.
Please read this manual completely before using your indicator. This information will enable you to fully
utilize the equipment and should be located nearby for reference. The indicator is intended to be used only in
the manner outlined in this manual. Misuse of the equipment may cause product failure.

Note: The Models S310 and S310D are identical to each other in every respect except the analog meter. The
S310 has both analog and digital displays. The S310D has only a digital display. All references to the S310 are
intended to include the S310D except where noted. Also the words "indicator" and "meter" are synonymous.

D

ETECTOR

O

PERATING

P

ARAMETERS

:

Note: All detectors are calibrated at a specific wavelength and the detector’s operating

parameters are derived for that wavelength. This information is recorded below and on
the detector’s serial tag. When a detector is used at a wavelength other than the
calibration wavelength some of the operating parameters may need to be adjusted. For
specific instructions please refer to the Operating Procedures section for the type of
detector you are using.



Calorimeter 1:

Calorimeter 2:

Model No:

___________

Model No:

__________

Serial No:

___________

Serial No:

__________

Group No:

___________

Group No:

__________

Calibration Wavelength

___________nm or µm

Calibration Wavelength:

__________nm or µm

Output Sensitivity (S):

___________V/W

Output Sensitivity (S):

__________V/W

Time Constant (1/e):

___________sec.

Time Constant (1/e):

__________sec.

Calibration Temp:

___________

°C Calibration

Temp:

__________°C

Sub. Heater Resistance (Rc): ___________ohms

Sub. Heater Resistance (Rc): __________ohms

Sub. Heater Voltage (Vh): ___________volts

Sub. Heater Voltage (Vh): __________volts

Sub. Heater Wattage (Wh) ___________watts

Sub. Heater Wattage (Wh): __________watts



Pyroelectric Detector 1:
Model No:

__________

Serial No:

__________

Group No:

__________

Calibration Wavelength:

__________nm or µm

Output Sensitivity:

__________V/J or __________V/mJ S_________ I__________ L_________

Calibration Temp:

__________°C



Pyroelectric Detector 2:
Model No:

__________

Serial No:

__________

Group No:

__________

Calibration Wavelength:

__________nm or µm

Output Sensitivity:

__________V/J or __________V/mJ S_________ I_________ L__________

Calibration Temp: