Scientech S310 Vector User Manual
Page 2
![background image](/manuals/710621/2/background.png)
2
Thank you for choosing a Scientech laser power and energy meter. Scientech, an ISO 9001 registered
company, and our employees are pleased to provide you with a product designed for years of reliable service.
Please read this manual completely before using your indicator. This information will enable you to fully
utilize the equipment and should be located nearby for reference. The indicator is intended to be used only in
the manner outlined in this manual. Misuse of the equipment may cause product failure.
Note: The Models S310 and S310D are identical to each other in every respect except the analog meter. The
S310 has both analog and digital displays. The S310D has only a digital display. All references to the S310 are
intended to include the S310D except where noted. Also the words "indicator" and "meter" are synonymous.
D
ETECTOR
O
PERATING
P
ARAMETERS
:
Note: All detectors are calibrated at a specific wavelength and the detector’s operating
parameters are derived for that wavelength. This information is recorded below and on
the detector’s serial tag. When a detector is used at a wavelength other than the
calibration wavelength some of the operating parameters may need to be adjusted. For
specific instructions please refer to the Operating Procedures section for the type of
detector you are using.
Calorimeter 1:
Calorimeter 2:
Model No:
___________
Model No:
__________
Serial No:
___________
Serial No:
__________
Group No:
___________
Group No:
__________
Calibration Wavelength
___________nm or µm
Calibration Wavelength:
__________nm or µm
Output Sensitivity (S):
___________V/W
Output Sensitivity (S):
__________V/W
Time Constant (1/e):
___________sec.
Time Constant (1/e):
__________sec.
Calibration Temp:
___________
°C Calibration
Temp:
__________°C
Sub. Heater Resistance (Rc): ___________ohms
Sub. Heater Resistance (Rc): __________ohms
Sub. Heater Voltage (Vh): ___________volts
Sub. Heater Voltage (Vh): __________volts
Sub. Heater Wattage (Wh) ___________watts
Sub. Heater Wattage (Wh): __________watts
Pyroelectric Detector 1:
Model No:
__________
Serial No:
__________
Group No:
__________
Calibration Wavelength:
__________nm or µm
Output Sensitivity:
__________V/J or __________V/mJ S_________ I__________ L_________
Calibration Temp:
__________°C
Pyroelectric Detector 2:
Model No:
__________
Serial No:
__________
Group No:
__________
Calibration Wavelength:
__________nm or µm
Output Sensitivity:
__________V/J or __________V/mJ S_________ I_________ L__________
Calibration Temp:
__________°C