Reznor B5SM Option - Installation - Smoke Detector - Light Commercial User Manual
Page 4

D200-94-00 4 I56-1222-03
© System Sensor 1999
WARNING
The sounder or sounder/strobe combination will not operate if the
power is cut off for any reason.
If power is cut off for any reason, the sounder or strobe/sounder combina-
tion will not provide the desired audible or visual warning.
The sounder may not be heard. The loudness of the sounder meets
or exceeds the current Underwriters Laboratories’ standards. However,
the sounder may not alert a sound sleeper or one who has recently used
drugs or has been drinking alcoholic beverages. This sounder may not be
heard if it is placed in an area that is separated by a closed door, or if it is
located on a different floor from the person in a hazardous situation, or
if it is placed too far to be heard over ambient noise, such as, traffic, air
conditioners, machinery or musical appliances that may prevent alert per-
sons from hearing the alarm. For these reasons, Pittway recommends that
sounders (85dBA minimum at 10 feet) used in a residence shall be placed
on every level and in every bedroom that does not have a smoke detector
with a built-in sounder.)
The sounder may not be heard by persons who are hearing-impaired.
In this case, a visual indicator shall also be used.
The Sounder and add-on strobe are for supplemental signaling only.
The signal strobe may not be seen. The electronic visual warning sig-
nal meets or exceeds current Underwriters Laboratories’ standards. The
visual warning signal is suitable for direct viewing and must be installed
within an area where it can be seen by building occupants. The strobe
must not be installed in direct sunlight or areas of high light intensity
where the visual flash might be disregarded or not seen.
The strobe may not be seen by the visually impaired.
The signal strobe may cause seizures. Individuals who have a positive
photic response to visual stimuli with seizure, such as epileptics, should
avoid prolonged exposure to environments in which strobe signals, in-
cluding this strobe, are activated.
System Sensor warrants its enclosed multi-signaling accessory to be free
from defects in materials and workmanship under normal use and ser-
vice for a period of three years from date of manufacture. System Sensor
makes no other express warranty for this multi-signaling accessory. No
agent, representative, dealer, or employee of the Company has the au-
thority to increase or alter the obligations or limitations of this Warranty.
The Company’s obligation of this Warranty shall be limited to the repair
or replacement of any part of the multi-signaling accessory which is
found to be defective in materials or workmanship under normal use and
service during the three year period commencing with the date of man-
ufacture. After phoning System Sensor’s toll free number 800-SENSOR2
(736-7672) for a Return Authorization number, send defective units post-
Ordering Information
SSK451
Multi-Signaling Accessory
PA400B
Mini-Alert™ Sounder, beige
PA400W
Mini-Alert™ Sounder, white
PS24LOB
Mini-Alert™ Add-On Strobe, beige
PS24LOW
Mini-Alert™ Add-On Strobe, white
PS12/24SLENSW
Smoke Lens Wall Mount
Innovair Duct Smoke Detectors
DH100ACDCP
4-Wire Photoelectric Duct Smoke Detector
DH100ACDCI
4-Wire Ionization Duct Smoke Detector
Other Accessories
RTS451
Remote Test/Reset Station
RTS451KEY
Key-Activated Remote Test/Reset Station
APA451
Piezo Annunciator
RA400Z
Remote Annunciator Alarm
ON
RESET
TEST
ALARM
ALARM
POWER
ALARM
RESET
TEST
Three-Year Limited Warranty
age prepaid to: System Sensor, Repair Department, RA #__________, 3825
Ohio Avenue, St. Charles, IL 60174. Please include a note describing the
malfunction and suspected cause of failure. The Company shall not be ob-
ligated to repair or replace units which are found to be defective because of
damage, unreasonable use, modifications, or alterations occurring after the
date of manufacture. In no case shall the Company be liable for any conse-
quential or incidental damages for breach of this or any other Warranty, ex-
pressed or implied whatsoever, even if the loss or damage is caused by the
Company’s negligence or fault. Some states do not allow the exclusion or
limitation of incidental or consequential damages, so the above limitation
or exclusion may not apply to you. This Warranty gives you specific legal
rights, and you may also have other rights which vary from state to state.
H0490-00
H0488-00
H0487-00
H0486-00
H0489-00
943B-0505
- R6GD Option - Installation - Smoke Detector - Light Commercial R6GN Option - Installation - Smoke Detector - Light Commercial R8GD Option - Installation - Smoke Detector - Light Commercial Q6SD Option - Installation - Smoke Detector - Light Commercial R6GP Option - Installation - Smoke Detector - Light Commercial P6SP Option - Installation - Smoke Detector - Light Commercial P6SD Option - Installation - Smoke Detector - Light Commercial Q6SP Option - Installation - Smoke Detector - Light Commercial