Reznor XAWU Unit Installation Manual User Manual
Page 4
PAGE 4
Stand Alone ERV’S For Over and Under In door Application
B
C
D
D
E
I
G
H
ERV Data
Di men sional Data
Size
CFM Range
A
B
C
D
E
F
G
H
I
J
K
11
300-1100
56.75
32.13
39.50
11.00
27.00
4.50
10.00
2.56
1.00
10.00
4.50
20
1200-2000
54.38
37.25
37.50
12.00
30.00
8.00
4.00
3.63
1.50
7.00
5.00
28
1200-2800
60.00
42.62
43.56
14.00
32.00
9.56
4.50
5.31
1.50
8.81
5.25
36
2000-3600
60.00
46.69
57.37
16.50
39.50
12.13
6.38
3.59
5.88
11.75
6.75
46
3000-4600
60.00
52.69
57.37
16.50
39.50
12.13
6.38
6.59
5.88
11.75
6.75
62
4600-6200
72.00
70.88
63.63
19.50
39.50
12.13
6.50
15.69
5.88
12.00
6.75
F
H
EXHAUST AIR
FRESH AIR
RETURN AIR
TREATED AIR
Fea tures and Notes
1.
Stand alone design allows higher levels of outdoor
air to be introduced into the conditioned space.
2.
Static test ports provided to verify intake and
exhaust CFM.
3.
Balancing damper(s) is field provided when connected
to ductwork. System may not operate properly without
balancing damper.
4.
See blower performance charts for airflow at various
E.S.P.
5.
Filter rack with 2" pleated filters included.
ERV with Hori zon tal Duct work
(bal anc ing damper(s) field sup plied)
A
D
D
I
K
J
- UDAP Unit Installation Manual (40 pages)
- UDBP Unit Installation Manual (44 pages)
- UEAS Unit Installation Manual (44 pages)
- VPS Unit Installation Manual (44 pages)
- VPT Unit Installation Manual (40 pages)
- VCS Unit Installation Manual (48 pages)
- CAUA Unit Installation Manual (44 pages)
- EEDU Unit Installation Manual (32 pages)
- LDAP Unit Installation Manual (44 pages)
- MASA Unit Installation Manual (40 pages)
- RDF Unit Installation Manual (28 pages)
- RPB Unit Installation Manual (40 pages)
- SC Duct Furnace Unit Installation Manual (40 pages)
- SSCBL Unit Installation Manual (60 pages)
- X Unit Installation Manual (32 pages)
- ZQYRA Unit Installation Manual (72 pages)
- ADF Unit Installation Manual (28 pages)
- F Unit Installation Manual (40 pages)
- PDH (Indoor PreevA) Unit Installation Manual (72 pages)
- MAPSIII Unit Installation Manual (76 pages)
- RDH (Outdoor PreevA) Unit Installation Manual (68 pages)
- RP (Outdoor Duct Furnaces) Unit Installation Manual (32 pages)
- YDHA Unit Installation Manual (76 pages)
- OH Unit Installation Manual (28 pages)
- RBL (Cabinet Blower) Unit Installation Manual (12 pages)
- REC (Evaporative Cooling) Unit Installation Manual (12 pages)
- RIHN Unit Installation Manual (20 pages)
- UDAP Option - Installation - Power Venting (12 pages)
- UDAS Option - Installation - Separated Combustion Venting (16 pages)
- WS Unit Installation Manual (15 pages)
- EBHB Option - Installation - Thermostat Kit (2 pages)
- EFMA Unit Installation Manual (27 pages)
- EWHB Unit Installation Manual (9 pages)
- EXUB Unit Installation Manual (16 pages)
- XAWS Unit Installation Manual (12 pages)
- XBWU Unit Installation Manual (12 pages)
- MAPS III Option - Installation - Energy Recovery Module Installation (12 pages)
- UDAP in sizes 30 through 125 Option - Installation - Ceiling Suspension Kit (2 pages)
- UEAS Option - Installation - Downturn Nozzles - V3 (4 pages)
- UDBP Option - Installation - Polytube Adapter Instructions (4 pages)
- UDBS Option - Installation - Vertical Louvers - V3 Series (2 pages)
- B Option - Installation - Blower/Filter Cabinet (4 pages)
- PDH with 1-stage gas control or 2-stage gas control Gas Conversion Kit Instructions (8 pages)
- VP series infrared heaters High altitude conversion instructions (12 pages)