Perfect Aire 1PAMSH22-15 User Manual User Manual
Page 6

5
OPERATING INSTRUCTIONS
Special functions
Improving the quality of indoor air is one of the purposes of an air conditioner. This air
conditioner is equipped with an ionizer or Plasma Dust Collector (depending on specific
configuration of the model). With the ions generated by the Ionizer, the air circulation
of the air conditioner fills the room with refreshing, natural and healthy air. The Plasma
Dust Collector generates a high voltage ionization zone, through which the air is
converted to plasma. Inside the air most of the dust, smoke, and pollen particles are
captured by the electrostatic filter.
CLEAN AIR function (on some models)
SELF CLEAN function (optional)
Anti-mildew function (optional)
When turning off the uniton “COOL”, “DRY”, “AUTO” (Cool) mode, the air conditioner will continue
operating for about 7-10 minutes (depending on models) with soft wind. This will help to
dry up the condensed water inside the evaporator, and prevent the breeding of mildew.
Under Anti-mildew operation, do not restart the air conditioner until the unit is completely off.
Function used after the Shut Down of cooling operation to clean the Evaporator
and keep it as fresh for the next operation.
The unit will operate as follows: “FAN ONLY” mode at Low fan speed--Heating
operation with “LOW” fan speed (applicable to cooling & heating models only) ---“FAN ONLY”
operation--Stop Operation---Turn off.
Note:
This function is only available under “COOL” (”AUTO COOL”, “FORCED COOL”) and “DRY” mode.
Before selecting the function, it is recommended to run the air conditioner under Cooling
operation for about half an hour. Once the Self Clean function is activated, all “TIMER”
settings will be cancelled.
During Self Clean operation, when the “SELF CLEAN” button is pressed on the remote
control again it will stop the operation and turn off the unit automatically.
Louver Angle Memory Function (optional):
Within the scope of safety angle, it will memorize the open angle of the horizontal louver.
If it is exceeded, it will memorize the boundry of safety angle. In the following circumstances,
it will return to standard angle: 1) pressing the turbo or manual control button.
So we strongly suggest that the open angle of the horizontal louver should not be set too
small, in case the condensed water forms and drops from the horizontal louver.
Refrigerant Leakage Detection
With this new technology, the display area will appear EC and the indication lamps
continue flashing when the outdoor unit detects refrigerant leakage.
,
,