11

OPERATION TIPS

The following events may occur during normal operation.
1. Protection of the air conditioner.

Compressor protection
The compressor can't restart for 3 minutes after it stops.
Anti-cold air (Cooling and heating models only)
The unit is designed not to blow cold air in “HEAT” mode, when the indoor heat exchanger is in
one of the following three situations and the set temperature has not been reached.

A) When heating has just started.

B) Defrosting is occurring.
C) Low temperature heating is occuring.
The indoor or outdoor fan stop running when defrosting (Cooling and heating models only).
Defrosting (Cooling and heating models only)
Frost may be generated on the outdoor unit during heat cycle when outdoor temperature is low
and humidity is high resulting in lower heating efficiency of the air conditioner.
During this condition air conditioner will stop heating operation and start defrosting automatically.
The time to defrost may vary from 4 to 10 minutes according to the outdoor temperature and

the amount of frost built up on the outdoor unit.

2. A white mist coming out from the indoor unit

A white mist may generate due to a large temperature difference between air inlet and air outlet

in “COOL”mode in an indoor environment that has a high relative humidity.

A white mist may be generated due to moisture generated from defrosting process when the air

conditioner restarts in “HEAT” mode operation after defrosting.

3. Low noise of the air conditioner

You may hear a low hissing sound when the compressor is running or has just stopped running.
It is the sound of the refrigerant flowing or coming to a stop.
You can also hear a low "squeak" sound when the compressor is running or has just stopped
running. This is caused by heat expansion and cold contraction of the plastic parts in the unit
when the temperature is changing.

A noise may be heard due to louver restoring to its original position when power is turned on.

4. Dust is blown out from the indoor unit.

This is a normal condition when the air conditioner has not been used for a long time or during first
use of the unit.

5. A peculiar smell comes out from the indoor unit.

This is caused by the indoor unit giving off smells permeated from building material, from furniture,
or smoke.

6. The air conditioner turns to “FAN” only mode from “COOL” or “HEAT” (For cooling and

heating models only) mode.

When indoor temperature reaches the temperature setting on air conditioner, the compressor will
stop automatically, and the air conditioner turns to “FAN” only mode. The compressor will start again
when the indoor temperature rises on “COOL” mode or falls on “HEAT” mode (For cooling and heating
models only) to the set point.

7. The air conditioner runs

function after turning off the unit.

When turning off the unit under “COOL” (”AUTO COOL”, “FORCED COOL”) and “DRY” mode, the air

conditioner will run

function for 7-10 minutes, then stop the operation and turn

off the unit automatically.

Anti-mildew

Anti-mildew