beautypg.com

Perfect Aire 1PAMSH22-15 Installation Manual User Manual

Room air conditioner, Installation manual for, Split wall-mounted type)

background image

1. Fit the installation plate horizontally
on structural parts of the wall with
spaces around the installation plate.
2. If the wall is made of brick, concrete
or the like, drill five or eight 0.2 inch
diameter holes in the wall. Insert Clip
anchor for appropriate mounting screws.
3. Fit the installation plate on the wall
with five or eight type A screws.

Mount the Installation Plate and drill
holes in the wall according to the
wall structure and corresponding
mounting points on the installation
plate. The installation plate provided
with the machine differ from appliance
to appliance.
(Dimensions are in inch unless
otherwise stated).

1. Determine hole positions according to left and right
side of the installation plate. The hole center is obtained
by measuring the distance as shown in the diagram above.
2. Dirll the piping plate hole with 2.5 inch hole-core drill.
3. Drill the piping hole at either the right or the left and the
hole should be slightly slanted to the outdoor side.
4. Always take steps to protect the pipe when drilling metal
grid, metal plate or the like.

INSTALLATION MANUAL FOR

ROOM AIR CONDITIONER

(Split Wall-Mounted Type)

DRILL A HOLE IN THE WALL

INSTALLATION PLATE MOUNTING

2

NOTE:

NOTE:

Installation Plate Mounting

1

The mounting wall is strong and solid
enough to prevent it from the vibration.

"

"

" "

I

N

D

O

O

R

U

N

I

T

Right rear side

refrigerant pipe

hole 2.6

Right rear side

refrigerant pipe

hole 2.6

Right rear side

refrigerant pipe

hole 2.6

Left rear side

refrigerant

pipe hole 2.6

Left rear side

refrigerant

pipe hole 2.6

Left rear side

refrigerant

pipe hole 2.6

6inch or more to ceiling

Indoor unit outline

Indoor unit outline

Indoor unit outline

4.8inch or

more to wall

4.8inch or

more to wall

Correct orientation

of Installation Plate

Except the above parts provided, the other parts needed during installation you must
purchase.

ACCESSORIES

NOTE:

6inch or more to ceiling

4.8 inch or

more to wall

4.8inch or

more to wall

SELECT THE BEST LOCATION

Please read these safety precautions carefully before installation

Be sure to follow all the precautions below, they are all important for ensuring safety.

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to property.

SAFETY PRECAUTIONS

CAUTION

WARNING

Please read this installation manual carefully before operating the unit to ensure correct installation.

Installation must be performed in accordance with the requirement of NEC and CEC by authorized

personnel only.

Contact an authorized service technician for repair, maintenance and installation of this unit.

This appliance is not intended for use by persons (including children) with reduced physical, sensory

or mental capabilities, or lack of experience and knowledge, unless they have been given supervision

or instruction concerning use of the appliance by persons responsible for their safety.

Children should be supervised to ensure that they do not play with the appliance.

All the pictures in the instructions are for explanation purposes only. The actual shape should prevail.

The design and specifications are subject to change without prior notice for product improvement.

Consult with the sales agency or manufacturer for details.

There should not be any heat source or stream

near the unit.

There should not be any obstacles blocking the

air circulation.

A place where air circulation in the room is good.

A place where drainage can be easily done.

A place where noise prevention is taken into

consideration.

Do not install the unit near the doorway.

Ensure the spaces indicated by arrows from the

wall, ceiling, fence or other obstacles.

There should not be any direct sunlight. If unavoidable,

sunlight prevention should be taken into consideration.

Outdoor unit dimension

inch(WxHxD)

A(inch)

18.1

B(inch)

9.9

20.9

11.5

21.6

10.9

Mounting dimensions

27.6 x 21.3 x 9.5
30.8 x 21.3 x 9.9
30 x 23.3 x 11.3

Indoor unit

Outdoor unit

If an awning is built over the unit to prevent

direct sunlight or rain, be careful that heat

radiation from the condenser is not obstructed.

There should not be any animal or plant which

could be affected by hot air discharged.

Keep the spaces indicated by arrow from wall

ceiling, fence or other obstacles.

Do not place any obstacles which may cause

a short circuit of the discharged air.

Settlement of outdoor unit

A

W

B

D

Air inlet

Air outlet

Air inlet

INSTALLATION PRECAUTIONS

CONNECT THE CABLE TO THE INDOOR UNIT

3

The cable size and the current of the fuse

or switch are determined by the maximum

current indicated on the nameplate which

is located on the side panel of the unit.

Please refer to the nameplate before

selecting the cable, fuse and switch.

Terminal block of indoor unit

Connect the cable to the indoor unit

NOTE:

Before performing any electrical work, turn off the power at the main panel to the unit.
1. The inside and outside connecting cable can be connected without removing the front grill.
2. Lift the indoor unit panel up, remove the electrical box cover by loosening the screw.
3. Ensure the color of wires of outdoor unit and the terminal Nos. are the same to the indoor units
respectively.
4. Wrap those cables not connected with terminals with insulation tapes, so that they will not touch
any electrical components. Secure the cable onto the control board with the cord clamp.

NOTE:

Electrical box
cover

Front Panel

••

••

••

••

1.4

4

••

••

••

9000Btu/h models(A:26.8, B:10.1, C:6.7, D:3.7)

12000Btu/h models(A:30.3, B:10.1, C:6.7, D:3.7)

18000Btu/h models(A:35.6, B:10.8, C:3.2, D:4)

A

A

A

C

C

C

D

D

D

B

B

B

6inch or more to ceiling

4.8inch or

more to wall

4.8inch or

more to wall

To outdoor unit

To outdoor unit

Cord clamp

1
2
3
4
5

7
8

9
10

6

Installation Plate

Clip Anchor
Self-tapping Screw A ST3.9x25
Seal (For cooling & heating models only)

Drain Joint (For cooling & heating models only

Connecting

pipe

Assembly

Liquid side

Gas side

Remote control

Air freshening filter (installed on Air filter)

Self-tapping Screw B ST2.9x10

Parts you must purchase. The pipe

size differs from appliance to appliance.

Consult the technician for the proper

size.

1
5-8(depending on models)

5-8(depending on models)

1
1

1
2

1

1

Remote control holder

Number Name of Accessories

Qty

optional

parts

4

CONNECTIVE PIPE AND DRAINAGE INSTALLATION

1. Run the drain hose sloping downward.

Do not install the drain hose as illustrated

in wrong figures.

2. When connecting extension drain hose,

insulate the connecting part of extension

drain hose with a shield pipe, do not let

the drain hose slack.

Drainage

Right

Wrong

L1 L2 S

L1 L2 S

or

Suggest Minimum Wire Size

(AWG:

):

American Wire Gage

Appliance Amps

AWG Wire Size

10

13

18

25

18

16

14

12

30

10

2020323B3338

Electrical work

(6 in)

(4.8in

)

(4.8in)

(7.55ft)

(11.

9in)

(2

3

.7

in

)

(11.9i

n)

(23.

7in)

(6.57ft

)

(0

.2

-0

.3

in

c

h

)

Electric safety regulations for the initial Installation
1. If there is any safety concerns with the electrical power supply the technician should consult a
certified electrician and have the problem resolved before installing the unit.
2. Power voltage should be in the range of 90%~110% of rated voltage.
3. The circuit breaker at the electrical panel should be no more than 1.5 times the max current of the
outdoor unit. All the electrical information is located on the reverse side of the electrical cover on the
on the outdoor unit. Follow all local and national electric codes.
4. Each outdoor unit must have its own circuit breaker.
5. Install the proper sized electrical wire from the circuit breaker located at the electrical panel to an
outdoor weather proof disconnect.
6. The outdoor unit must be grounded per code. If the unit is not grounded it will not operate per
system specifications.
7. Install a liquid tight electrical whip from the outdoor disconnect to the outdoor unit.
8. All wiring must comply with local and national codes and be installed by a certified electrician.

CAUTION

WARNING

1) Install according to these installation instructions. If installation is defective, it will cause water
leakage, electrical shock, or fire.
2) It will cause the unit to fall, have water leakage, give an electrical shock and/or cause a fire.
3) Install the indoor unit per these instructions. Make sure it is secured properly to the wall. If not
installed properly the unit could drop or fall causing injury.

4) An independent circuit breaker must be used for each indoor unit. If the circuit breaker is not sized
properly, it will cause an electrical shock and/or a fire.
5) Use the specified cable and connect properly to the terminals. If the cable is not connected
properly, it will cause a hot spot or fire at the connection.
6)

Wiring routing must be properly arranged so that control board cover is fixed properly. If control board

cover is not fixed properly, it will overheat at connection point of terminal, fire or electrical shock.
7) When connecting the refrigerant piping, make sure no debris or foreign matter gets into the
refrigerant piping.

1) This equipment must be grounded properly. Follow the local and national codes when choosing the
proper outdoor electrical disconnect. The unit will not run properly and could cause an electrical
shock if not installed properly.
2) Do not install the unit at place where leakage of flammable gas may occur. In case gas leaks and
accumulates at surrounding of the unit, it may cause fire.
3) Install condensate drain pipe as mentioned in the installation instructions. If drain is not installed
properly, water could back up in the system causing water damage.

The outdoor unit should be installed on a concrete or
plastic pad or mounted to a wall with the proper brackets
and secured per local and national codes.

NOTE: The outdoor unit you purchase may be like one

of the following. Install the outdoor unit according to the

dimension as indicated in the table below:

1/4 (6.35mm)

3/8 (9.52mm)
3/8 (9.52mm)

5/8 (16mm)

1/2 (12.7mm)