In the course of launch, PILOT 1200 examines automatically whether there are errors and if there are,
it will display information as follows:
INFORMATION
ERRORS
Er02
Sensor 1 temperature too high
Er04
Lamp error
Er05
EEPROM error
Er06
Sensor 2 temperature too high
Er09
Gobo rotation reset error
Er10
Gobo change reset error
Er11
Effect wheel reset error
Er12
Colour wheel reset error
Er17
Prism rotation reset error
Er18
Prism change reset error
Er20
Fixed gobos reset error
Er25
Pan motor reset error
Er26
Tilt motor reset error
PINCERS
ROTATED GOBO WHEEL
RETAINING SPRING
GOBOS
EFFECT WHEEL
FIXED GOBO WHEEL
Lock Tilt. Loosen 2 screws on the rear cover with fans and open the rear cover with fans. You could
see the structure as shown in the above figure.
For gobos replacement on the fixed gobo wheel: turn the effect wheel and rotated gobo wheel to a
proper position first; take out a gobo from the fixed gobo wheel carefully; fit a new gobo. Note: if the
gobo is a glass one, it should be touched with glabrous, clean and soft tissue or cloth matted between
hand and glass instead of with bare hand.
For filters replacement on the effect wheel: do in the same way of fixed gobo wheel.
For gobos replacement on the rotated gobo wheel: take an appropriate tool to tug the head of
retaining spring up and engage your another hand to take the retaining spring out; take the gobo out;
fit a new gobo and fit the retaining spring. Notes: the gobo cannot be touched with bare hand; never
attempt to dismantle the gobo holder on which you want to replace the gobo; be careful of the gobo
when the replacement is underway and don’
t drop it.
Close the rear cover and fasten 2 M5 screws.
ERRORS DISPLAY
REPLACING GOBOS