In the course of launch, PILOT 1200 examines automatically whether there are errors and if there are,
it will display information as follows:

INFORMATION

ERRORS

Er02

Sensor 1 temperature too high

Er04

Lamp error

Er05

EEPROM error

Er06

Sensor 2 temperature too high

Er09

Gobo rotation reset error

Er10

Gobo change reset error

Er11

Effect wheel reset error

Er12

Colour wheel reset error

Er17

Prism rotation reset error

Er18

Prism change reset error

Er20

Fixed gobos reset error

Er25

Pan motor reset error

Er26

Tilt motor reset error




PINCERS

ROTATED GOBO WHEEL

RETAINING SPRING

GOBOS

EFFECT WHEEL

FIXED GOBO WHEEL

Lock Tilt. Loosen 2 screws on the rear cover with fans and open the rear cover with fans. You could
see the structure as shown in the above figure.

For gobos replacement on the fixed gobo wheel: turn the effect wheel and rotated gobo wheel to a
proper position first; take out a gobo from the fixed gobo wheel carefully; fit a new gobo. Note: if the
gobo is a glass one, it should be touched with glabrous, clean and soft tissue or cloth matted between
hand and glass instead of with bare hand.

For filters replacement on the effect wheel: do in the same way of fixed gobo wheel.

For gobos replacement on the rotated gobo wheel: take an appropriate tool to tug the head of

retaining spring up and engage your another hand to take the retaining spring out; take the gobo out;

fit a new gobo and fit the retaining spring. Notes: the gobo cannot be touched with bare hand; never

attempt to dismantle the gobo holder on which you want to replace the gobo; be careful of the gobo

when the replacement is underway and don’

t drop it.


Close the rear cover and fasten 2 M5 screws.