beautypg.com

Connect, Light, Information – OmniSistem Spark 7 Zoom User Manual

Page 17

background image

 

Scenes Record 

ScXX=>ScXX 

Auto Input Scenes 

 
 

Connect 
 

DMX Address Setting 
With this function you can adjust the desired DMX address via the Control Board. 
Select “DMX Address“ by pressing Up or Down. 
Press the Enter button then adjust the DMX address by pressing Up or Down. 
Press the Enter button to confirm. 

 

Light 
 

Max Temperature 

With this function you can set the inside temperature at which the projector will automatically switch the lamp

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

off. Press Up or Down to select the maximum internal temperature between 80°C and 139°C. Internal

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

temperatures below 90°C are not critical. 90°C and more should lead to the lamp being switched off after five

 

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

minutes. Please note that the outside temperature should not exceed 45°C. 

 

Information 

 
Current Time Information 

With this function you can display the temporary running time of the device from the last power on. The display

 

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

shows “XXXX”, “X“ stands for the number of hours. The counter is reset after turning the device off. 

 

Fixture Life 

With this function you can display the running time of the device. The display shows “XXXX”, “X“ stands for the

 

 

 

 

 

 

 

 

   

 

 

 

 

 

 

 

 

 

 

number of hours.

 

 

Temperature Near Lamp Temp 

With this function you can display the temperature in the projector head in degrees Celsius/Fahrenheit. 

 

Fan speed 
With this function you can display the current fan speed. The display shows “XXXX”, “X“ stands for Hz. 

 

Initial status 
With this function you can display which value the respective channels will start. 

 

Error channels 
With this function you can display the channel errors. 

 

Fixture Model 
With this function you can display the model number and brand of the fixture. 

 

Software version 
With this function you can display the software version of each IC. 

1. Select “Software ver.” by pressing Up or Down. 
2. Press the Enter button. The display shows e.g. “1U01 VX.X.XX”, “X.X.XX“ stands for the version number. 

 

Set 

Reset 
With this function you can reset the device via the Control Board. You can select the different Reset­ functions 
by pressing Up or Down. 

 

Movement  
 
PAN Reverse
 
With this function you can reverse the pan movement. 

17 of 25