NORAC UC5-BC-HG04 User Manual
Page 25
22
Figure 21: Valve Module Bracket Installation
5. Connect the valve module CANbus to cable C01 from the chassis roll sensor. Route cable
C02 from the other CANbus connector to the 8-way coupler.
6. With the valve module securely mounted to the valve block, connect the valve cables (C10),
to the valve coils.
7. Connect cables C11 to outputs 5, 6 and 7 on the valve module.
8. Route the three cables (C11) to the Hagie valve block.
9. Disconnect the Boom Up solenoid and insert the connector on cable (C11) that is
connected to output 5 on the valve module.
10. Disconnect the Boom Down solenoid and insert the connector on cable (C11) that is
connected to output 6 on the valve module.
11. Disconnect the Lock valve and insert the connector on cable (C11) that is connected to
output 7 on the valve module.
12. 2-pin receptacles (P02) are provided to install onto the disconnected Hagie connectors.
Install these receptacles to keep the unused Hagie connectors from corroding.
13. Insert the 2-pin plugs (P01) into the unused 2-pin connectors on the valve module.