17

7.2

Valve Block Assembly

1. On a clean surface remove the plastic plugs from the block.

2. Install the orifice F09 into the B port of the 3

rd

station of the block.

3. Install the orifice F08 into the A port of the 3

rd

station of the block.

4. Mount the NORAC valve block to the sprayer valve mounting bracket.

5. Follow Figure 3 for the remainder of the plumbing.

6. When plumbing the system, the “B” lines of the NORAC valve block must be connected to

the Hagie “raise” lines.

7. The “A” lines of the NORAC valve block must be connected to the Hagie “lower” lines.

Figure 15: Valve Mounting Location

NORAC

Valve
Block