Hydraulic Installation

Ensure all pressure has been bled from the system before disconnecting any lines
or fittings. Hydraulic pressure will exist on the wing tilt circuits unless the wings
are being supported by other means. The hydraulic installation may be performed
with the wings in transport position, resting on the ground or with the tilt cylinders
fully extended.

Component failure due to oil contamination is not covered under the NORAC UC5
system warranty. It is recommended that a qualified technician perform the
hydraulic installation.

7.1

Linear Roll Cylinder Assembly

1. Remove the linear roll cylinder and components from the crate and install each component

as shown in Figure 11 and Figure 12.

Figure 11: Linear Roll Cylinder Assembly

2. The sensor bracket must be mounted to the end of the cylinder with no hoses

3. The boom target must be mounted to the end of the cylinder with hydraulic ports.

4. Align the spring target by rotating the metal casing around the linear roll cylinder.

5. The cylinder target (bottom rod) must be aligned so it is offset by 5/8” from the top rod.