9

The sensors should be oriented forward
(ahead) of the boom (see Figure 6 and
Figure 8).

When installing the UC4+ sensors

(E02), start with the smallest serial
number on the left hand side
proceeding to the largest serial
number on the right hand side
(Figure 9).

5. Sensor cables should run through the

mounting bracket tube and then behind
the member the bracket is mounted onto.
Cable-tie the connector in place. The
cable must not be allowed to hang below
the boom (Figure 6).

Figure 6 – Another Acceptable Mounting

Avoid

mounting

sensors

in

locations where they may read
from parts of the boom.

Figure 7 – Poor Mounting

(Sensor Reading off Boom)

General mounting rules for UC4+
ultrasonic wing sensors:

a) In its lowest position, the sensor

mouth must be 9 inches or more
from the ground.

b) The bottom of the sensor must be at

least 9 inches in front of the spray
nozzles.

c) The bottom of the sensor must be at

least 9 inches above the spray
nozzles.

d) Ensure that there are no obstructions

within a 12-inch diameter circle
projected directly below the center of
the sensor.

e) The sensor should be approximately

vertical at normal operating heights.

Figure 8 – Sensor Mounting Guidelines

A

B

B

D

C

Ultrasonic
Acoustic Cone