1 boom roll sensor mounting, 2 chassis roll sensor mounting – NORAC UC4+BC+FT1 User Manual
Page 14
11
4.2.1 Boom Roll Sensor Mounting
The boom roll sensor (E04) must be
mounted to the rotating part of the boom.
Follow these guidelines and refer to Figure
11 to mount the sensor.
a) Make sure you are using the roll sensor
that does NOT have a temperature
probe (only one cable) (E04).
b) The boom roll sensor must be mounted
to the rotating part of the boom
suspension.
c) Use cable-ties to secure the bracket to
a square edge feature (square tube).
d) Ensure the AMP (circular) connector
exits towards the Right Hand Wing
(when looking from the rear of the
sprayer).
e) Securely cable-tie the connector to the
frame.
4.2.2 Chassis Roll Sensor Mounting
The chassis roll sensor must be mounted to
a non-rotating part of the boom. To mount
the chassis roll sensor, follow the following
guidelines and refer to Figure 11.
a) Make sure you are mounting the roll
sensor that does have a temperature
probe (2 cables) (E03).
b) Mount the chassis roll sensor (E03) to a
non-rotating part of the boom.
c) Cable-tie the bracket to a square edge
feature (square tube).
d) The AMP (circular) connector MUST
exit towards the Right Hand Wing
(when looking from the rear).
e) Securely cable-tie the connector to the
frame.
Figure 11: Boom and Chassis Roll Sensors Correctly Mounted
E04
E03