beautypg.com

2 roll sensor installation – NORAC UC4+BC+FT1 User Manual

Page 12

background image

9

4.2 R

OLL

S

ENSOR

I

NSTALLATION

Mount the roll sensors to the included roll
sensor brackets using the machine screws and
nylon lock nuts. (Figure 7)

The roll sensors must be mounted

tightly to the brackets.

Figure 7: Mounting the Roll Sensor to the

Roll Sensor Mounting Bracket

When mounting the roll sensors use the
following guidelines and refer to Figure 8.
The smaller the distance between A and B in
Figure 8, the better the performance will be.

Distance A cannot be more than 12”.

a) The roll sensors must not be mounted

below the pivot point.

b) Ensure the roll sensors are sitting relatively

level when the sprayer chassis and boom are
level.

c) Both roll sensors must be mounted with the

circular AMP connector facing towards the
Right-Hand Wing (when looking from the
rear of the sprayer).

Figure 8: Mounting Guidelines for Center Pivot Sprayers

Connectors towards
Right-hand Wing 