15

4.5.2 Chassis Roll Sensor Mounting

The chassis roll sensor must be attached to
the chassis of the sprayer. To mount the
chassis roll sensor, refer to the following
guidelines.

1. The chassis roll sensor does not have a

temperature probe (E04).

2. Cable-tie the bracket to a square edge

(square tube).

3. The AMP (circular) connector must exit

towards the right hand wing (when
looking from the rear).

Figure 13: Chassis Roll Sensor Mounting Location


4.5.3 Temperature Probe

Fasten the temperature probe (E03) to the
UC4+ valve block using the included
3/8x1/2” bolt as illustrated in Figure 14.

Figure 14: UC4+ Valve Block with

Temperature Probe Installed