Page 27

background image

24

4.7.3 Hydraulic Plumbing

WARNING!

From this point in the installation the
booms will be inoperative until the
electronics are fully installed.

1. After the NORAC valves are mounted, the

hydraulic hoses and fittings can be plumbed.
The plumbing for the hydraulic circuit is
shown schematically in Figure 3.

2. Tee hose H70 into the port on the priority

valve labeled “EF”. This is located on the left
hand side, under the rear corner of the cab

outside the frame. Use the 12FORXOR-
12MORT Tee fitting (F11) (Figure 31).

Figure 31: Secondary Pressure Line (H70)

(teed into the priority valve EF port)

3. Route hose H70 to the NORAC valve

block, following existing hoses.

4. Attach the 6FORXR-6MORT tee fittings

(F10) to the “P” and “T” ports on the
NORAC Valve block.

5. Attach hose (H70) to the 6FORXR-6MORT

tee fitting (F10) in the “P” port on the
NORAC valve block.


6. Tee hose H71 into the inlet on the sprayer’s

hydraulic in-line filter using a 6FORXR-
6MORT tee fitting (F10). (Figure 32)

Figure 32: Secondary Tank Line (H71)
(teed into the tank return near the in-line
filter)

The load-sense return line (also teed

into the in-line filter) has an orifice
between the fittings. Ensure the
orifice is located in a manner that it
will not restrict the flow of the new
tank line (H71). In Figure 33,
illustration A shows the original

plumbing of the load sense return
and orifice. B and C show two
options for installation of the tee
fitting.

Tee Fitting

(F10)

Hose H71

In-line Filter