4. Remove the o-rings from the four aluminum pistons taking care not to scratch the o-ring gland.
Clean the pistons thoroughly using a clean paper towel. Install the new greased o-rings
supplied in the rebuild kit.
4
.
4
.
3.
Next, check the serial number of your SyncPRO™ (the
serial number label is located on back panel of unit).
Units with the letter B or M in the 7
th
digit (XXXXXXBXXX, or
XXXXXXMXXX) contain a water based fluid and can safely be
disposed down a drain.
Units with the letter C in the 7
th
digit of the serial number
(XXXXXXCXXX) contain a petroleum based mineral oil and
should be disposed with your other oils in accordance with the
laws of your locality.
Dispose of the existing fluid in the reservoir as indicated
above. Flush any remaining fluid from the assembly under
running water until the rinse water runs clear. Soapy water
may be used to help rinse units with oil based fluid. Wipe
off the outside of the reservoir and tubes with a clean paper
towel and use compressed air to gently blow water out of
the four chambers. You will need to force air down through
the tops of the tubes to blow out any remaining water.
Repeat this process until all of the water is removed. A very
small
amount of residual moisture is acceptable if it can’t be
completely removed.
3
.
5. Before going to the next step, make sure that the 4 tubes and o-rings are still fully seated in
the reservoir. If an o-ring pops up, simply re-seat the o-ring by pressing it back into place with a
small flat-blade screwdriver. When the tubes are properly seated and in place all of the notches on
the tubes will line up.
Re-seating o-ring with small
flat blade screwdriver
5
.
O-ring popped out of place
O-rings seated properly
5
.
5
.