Specifications

PHYSICAL AND ENVIRONMENTAL

Drop test

3’ (1m) drop to concrete

Operating temperature range

14°F to 122°F (-10°C to +50°C)

Operating and storage humidity range

10% to 90%, non-condensing

Storage temperature range without battery1

-13°F to 140°F (-25°C to +60°C)

TEMPERATURE MEASUREMENT

Infrared (IR) resolution

160 X 120 pixels (picture elements, or data points)

Object temperature range2

14°F to 662°F (-10°C to 350°C)

Thermal sensitivity

0.1°C per 30°C Noise Equivalent Temperature Difference (NETD)

Spatial resolution

2.7 mrad Instantaneous Field of View (IFOV)

Accuracy

±4°F (2°C) or ±2% or reading, whichever is greater

On-board adjustable emissivity

Variable from 0.01 to 1.00, in increments of 0.01

Infrared (IR) detector type

Uncooled microbolometer focal-plane array (FPA)

Spectral range

8 to 14 μm

THERMAL IMAGING

Field of view (FOV)

25° Horizontal X 19° Vertical

Focus method

Manual

Minimum distance in focus

3.9”.(10 cm)

Screen refresh

60 Hz