CAUTION

Set the Rotary Dial to an appropriate position before starting measurement.
Disconnect test leads from test points before changing Rotary Dial functions.
Never connect to a source of voltage with the Dial function in OFF/Ω/ / / /

/ .

Firmly insert the test leads.
Do not expose the instrument to the direct sun, high temperature and humidity or dew fall.
Altitude 2000m or less. Appropriate operating temperature is within -10ºC and 50ºC.
Keep away from excess dust and water.
Be sure to power off the instrument after use. When the instrument will not be in use for a long

period, place it in storage after removing the batteries.
Use a damp cloth or neutral detergent for cleaning the instrument. Do not use abrasives or

solvents.

Accuracy is specifi ed for 1 year after calibration, at operating temperatures of 18°C to 28°C (64°F to

82°F), with relative humidity at 45 % to 85 %.

General Specifi cations

FUNCTIONAL DESCRIPTION

1. Display
2. Range button
3. °F/°C button
4. Backlight button
5. VΩ Terminal input
6. COM Terminal input
7. A mA Terminal input
8. Rotary Dial
9. Min/Max button
10. Hold button
11. Accessory bay (on back, not shown)

4

2

1

3

5

6

7

8

9

10

Maximum voltage between

any terminal and earth ground

600 V Cat III Rated

Temperature

Operating: -10°C to 50°C (14°F to 122°F)

Current measurements: -10°C to 40°C (14°F to 104°F)

Storage: -40°C to 60 °C (-40°F to 140°F)

Temperature Coeffi cient

0.1 x (specifi ed accuracy)/°C (<18°C or >28°C)

Operating Altitude

2,000 meters

IP Rating (International Dust

& Water Protection)

IP54

Drop Test

1 Meter

Battery

2 AA, NEDA 15 A,IEC LR6

Battery Life

Approx. 26 Hours all lights on

Fuse

600V AC/DC, 10A Fast-acting (Milwaukee p/n 22-89-0305)

Safety Compliances

EN61010-1, UL 61010-1, UL 61010-031 (Probes), EN61010-031

(Probes), IEC/EN 61010-1 2nd Edition for measurement

Category III, 600 V, Pollution Degree 2, EMC EN61326-1

Certifi cations

cULus, CE

Symbology

Read Operator’s Manual

Double insulation

Risk of electric shock

Earth

Danger, Warning, or Caution - Consult the operators manual for additional safety
information.

Battery compartment

European Conformity Mark

Underwriters Laboratories, Inc.,
United States and Canada

Cat III

Classifi cation of transient overvoltages, based on nominal
line voltage to earth.

Fuse

Do not dispose of this product as unsorted municipal waste.