Lippert Components In Wall Slide-Out System User Manual
Page 16

3-2 Checking Fuses
The Total Control 1Slide requires a minimum of 30 amp fuse. Check the 12 volt fuse box for blown
fuses, and replace any if necessary. Consult the rv manufacturers documentation for the location
of the 12 volt fuse box, and the location of the Room Slide Controller’s fuse. If the fuse blows
immediately upon replacement, there is a problem with the wiring to the In-Wall™ Slide control box.
Have qualified service personnel check and repair.
3-3 Obstructions
Check outside the rv for possible obstructions: tree, post, car, ect… Check inside the rv for any
obstructions: luggage, furniture, open cabinets, ect… Also check for smaller objects that may be
wedged under the floor or in the sides of unit. Remove obstructions before proceeding.
3-4 Error Codes
Consult rv manufacturer’s documentation for the location of the Total Control 1 Slide Controller. See
page 1-8 for a description of the error codes, and possible problems.
3-5 Low Voltage
The Total Control 1 Slide Controller is capable of operating the room with as little as 8 volts. But
at these lower voltages the amperage requirement is greater. Check voltage at the controller, see
page C-5 for the location of power connections. If voltage is lower than 11 volts, it is recommended
that the battery be placed on a charger until it is fully charged. It may be possible to ’jump’ the rv’s
battery temporarily to extend or retract the room. Consult the rv manufacturer’s owners manual on the
procedure for ‘jumping’ or charging the battery.
**********Never ‘jump’ or charge the battery from the power connections
on the In-Wall™ Controller. Always do this at the battery.*****************
3-6 Only 1 side moving
The Total Control 1 Room Slide has a separate moto
r
to operate each side of the room. Does only 1
side of the room move a short distance (2 to 4 inches) and stop.
3-7 Will non moving side move with help
If only 1 side of the room is moving as in 3-6 above, then with someone’s assistance press the switch
to extend or retract the room while pushing the non moving side in the appropriate direction. On larger
rooms it may be necessary to have 2 or more people pushing the room.
3-8 Non moving side moved manually
Try to push the non moving side in and out. If a motor shaft has broken then it will be possible to
move that side of the room several inches by hand. Larger rooms may require several people to push.
3-9 With motor disengaged can room be moved?
Disengage motor, see 2-2 to disengage motor. After disengaging the motor is it possible to move the
room by hand? On larger rooms more than 1 person may be required to move the room.
3-10 Debris in the rack
Check all 4 gear racks on the side of the room for debris.
3-11 Do status led’s light
Consult the rv manufacturers documentation for the location of the Total Control 1 Controller. When
the room slide direction switch is actuated, do the status led’s light up. Check this in both the extend
and retract modes. See page 3 for the location of the status led’s. If the led’s do not light up, or
only light in 1 direction, then un-plug and re-plug the direction switch connection on the board. This
connection is shown on page 4. If the problem persists, the led’s still do not light up in both directions,
then the switch or the wiring between the switch and the room is defective.
3-12 Increase motor amperage
See page 4 for stall force calibration. Only increase stall force enough to cycle room effectively.