TROUBLESHOOTING CHART
The folowing troubleshooting chart outlines some common problems, their causes and possible
corrective actions. When reference is made to a “Power Unit,” the term includes the motor and
the actuator as a complete unit. All Power Units are shipped from the factory with a serial number
and date code, which should be given to the service technician when asking for assistance.
Notes:
If the slideout room will not retract there is a manual override that is located on the opposite the
motor on the gearbox. Once you have the room in the closed position take you unit to the closest
dealer. See pages 9-11 for Manual Override Instructions.
Switch related problems:
•
If room moves opposite from what the switch plate indicates, reverse the
motor wires on the back of the switch. Wire size must be 10ga. min.
•
If a gear is stripped, the entire gearbox must be replaced.
ROOM DOESN’T MOVE WHEN SWITCH IS PRESSED
PROBABLE CAUSE
CORRECTIVE ACTION
Restriction or obstruction inside or outside of unit
Check for and clear obstruction
Low battery voltage, blown fuse, defective wiring
Check battery voltage and charge if needed
Find and check fuse, replace if blown. Check
battery terminals and wiring. Look for loose
disconnected or corroded connectors.
Excessive room drag
Check that transit bars are removed
POWER UNIT RUNS, ROOM DOES NOT MOVE
Motor turns, room does not move
Gear key is broken or lost, replace gear
drive assembly
Broken gear on drive shaft
Replace gear drive assembly
Broken gear in gearbox
Replace motor/gearbox assembly
Bad motor or gearbox
Replace motor/gearbox assembly
POWER UNIT RUNS, ROOM MOVES SLOWLY
Low battery, poor ground, extremely low
Charge battery, check ground wire
temperature
Room in bind
Adjust to proper room setting
Incorrect height adjustment
Check for proper room height
ROOM STARTS TO MOVE AND STOPS
Low battery voltage, blown fuse, defective wiring
Check battery voltage and charge if needed
Find and check fuse, replace if blown. Check
battery terminals and wiring. Look for loose
disconnected or corroded connectors.
Obstruction of room inside or outside
Check for and remove any obstruction
Dirts or corrosion build up on mechanism
Clean dirt or corrosion and coat
LIGHTLY with oil
ROOM CHATTERS DURING OPERATION
Teeth on gear drive broken or worn
Replace gear drive assembly
Teeth on inner rail broken or worn
Replace inner rail assembly