Installation - rear sensor, Aftermarket manual – Lippert Components Ground Control 3.0 Aftermarket User Manual
Page 5
Ground Control
™
3.0
Aftermarket Manual
www.lippertcomponents.com (574) 537-8900
Rev: 12.01 - Ground Control™ 3.0 Aftermarket Manual
5
Installation - Rear Sensor
NOTE: For this portion of the installation, use parts R, S, T,
and U on the parts list. L is referenced but not needed.
The rear sensor (S) must be installed on the crossmember
to the rear of the back axle, centered from curbside to
roadside on the unit with the arrows on the top of the
sensor pointing the correct direction (Fig. 4).
1. Dry fit the mounting plate (T) and the rear sensor (S) to
the crossmember. The pre-drilled holes in the plate are for
mounting the plate to the crossmember. Mark on the plate
where the rear sensor will set. Space between the sensor
and the crossmember must be left so the wire harness will
not be pinched (Fig. 5).
2. Attach the rear sensor (S) to the mounting plate (T)
using two #8 x 1” self tapping screws (U). Orientation is
imperative for the correct operation of the leveling system
(Fig. 6).
Fig. 4
Detail of Fig. 4
Fig. 5
#8 x 1”screw
rear sensor
rear sensor
mounting plate
Fig. 6