KERN & SOHN ILJ 25K-4CM User Manual
Page 63

ILJ-C/ILS-C-BA-e-1320
63
Return to weighing mode
Press MODE and F1 WEIGHING will be displayed. Confirm by pressing PRINT and
the weighing scale will change to weighing mode.
Determining reference weight by weighing
The ENTER REFERENCE WEIGHT function is allocated to the F2-key.
Go to menu and select P2.6 DEVIATION
Use the arrow keys to select P2.6.5 SHORTCUTS
Press F2, P2.6.5.1 will be displayed along with the previous function for the
F1-key.
Press F1 and entry for the F2-key will take place
Press F2.
Use the arrow keys to select ENTER REFERENCE WEIGHT and
Confirm by PRINT; this function has now been allocated to F2.
In weighing mode:
This completes setting the operating
mode weighing by percentage.
The previously entered reference
weight will be displayed on the info
line.
Use the arrow keys to enter the
reference weight equalling 100%
and confirm by pressing PRINT.
(example)
Example: 2 kg
The reference weight of 2 kg has now been saved
as 100% value.
Remove reference weight and place load. The weight will be displayed in