360 dvs series direct vent fireplaces – Vermont Casting 360DVSL User Manual

Page 32

background image

32

360 DVS Series Direct Vent Fireplaces

10006326

D

E

F

OFF

P

ILOT

ON

FC108

Fig. 48 Replace regulator.

10. Reassemble fireplace in the reverse order, except

for the window frame assembly. Leave this off until
after unit has been checked for leaks and the gas
supply has been bled.

11.After bleeding the gas line and checking for leaks

with a soap solution, replace the window frame
assembly.

12. Fire up the unit. Check for flame impingement on

the logs, adjusting them as necessary.

13. Check manifold and supply pressures against the

appliance specifications.

The procedure for converting from one
gas to another is the same regardless of
the initial gas used. The only variations
are in orifice sizes and component part
numbers. Your authorized service pro-
vider will ensure correct parts are used.

L

OH

I

Regulator Cap

Conversion
Screw

Pressure
Regulator
Housing

HV120

Fig. 49 Honeywell conversion screw replacement.

Honeywell Gas Control Valve (Fig. 49)

The Honeywell valve fitted to this unit is suitable for use
with LP or Natural Gas. It is converted to the required
gas application by installing a color-coded conversion
screw.

a) Using a suitable small screwdriver, lift out the
central regulator cap from the “HI/LO” knob on the
valve.

b) Unscrew the exposed conversion screw.

c) Insert the new color coded conversion screw. Do
not overtighten the screw; it must be finger- tight.

d) Refit the regulator cap.

e) Mount conversion label supplied with the conver-
sion screw to the valve in a visible position.