beautypg.com

For your safety, read before lighting, 360 dvs series direct vent fireplaces, Lighting instructions – Vermont Casting 360DVSL User Manual

Page 26

background image

26

360 DVS Series Direct Vent Fireplaces

10006326

1. STOP! Read the safety information above.
2. Turn off all electrical power to the fireplace.
3. For MN/MP/TN/TP appliances ONLY, go on to

Step 4. For RN/RP appliances turn the On/Off
switch to “OFF” position or set thermostat to
lowest level.

4. Open control access panel.
5. Push in gas control knob slightly and turn

clockwise

to "OFF".

FOR YOUR SAFETY, READ BEFORE LIGHTING.

If you cannot reach your gas supplier, call
the Fire Department.

C. Use only your hand to push in or turn the gas

control knob. Never use tools. If the knob will not
push in or turn by hand, do not try to repair it, call a
qualified service technician. Applying force or any
attempted repair may result in a fire or explosion.

D. Do not use this fireplace if any part has been under

water. Immediately call a qualified service techni-
cian to inspect the heater and to replace any part of
the control system and any gas control which has
been under water.

To Turn OFF Gas to Heater

Lighting and Operating Instructions

1. Turn the On/Off switch to Off position or set the

thermostat to lowest setting.

2. Turn off all electric power to the fireplace if service is

to be performed.

Lighting Instructions

WARNING: If you do not follow these instructions exactly, a fire or explosion

may result, causing property damage, personal injury or loss of life.

Euro SIT

SIT NOVA

Honeywell

A. This heater has a pilot light, which must be lit

manually. When lighting the pilot follow these
instructions exactly:

B. BEFORE LIGHTING, smell all around the

heater area for gas. Be sure to smell next to the
floor because some gas is heavier than air and
will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace.

Do not touch any electric switch.

Do not use any phone in your building.

Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.

10. Push the control knob all the way in and hold.

Immediately light the pilot by repeatedly depress-
ing the piezo spark igniter until a flame appears.
Continue to hold the control knob in for about one
(1) minute after the pilot is lit. Release knob and it
will pop back up. Pilot should remain lit. If it goes
out, repeat steps 5 through 8.

If knob does not pop up when released, stop
and immediately call your service technician or
gas supplier.

If after several tries, the pilot will not stay lit,
turn the gas control knob to "OFF" and call
your service technician or gas supplier.

11. Replace glass door.
12. Turn gas control knob to “ON” position.
13. For RN/RP appliances turn the On/Off switch to

“ON” position or set thermostat to desired setting.

14. Turn on all electrical power to the fireplace.

6. Wait five (5) minutes to clear out any gas. Then

smell for gas, including near the floor. If you
smell gas, STOP! Follow "B" in the safety
information above. If you do not smell gas, go
to the next step.

7. Remove glass door before lighting pilot. (See

Glass Frame Removal section).

8. Visibly locate pilot by the main burner.
9. Turn knob on gas control counterclockwise

to "PILOT".

3. Open control access panel.
4. Push in gas control knob slightly and turn clockwise

to "OFF". Do not force.

5. Close control access panel.

PILOT

ON

OFF

ON

PILOT

O

F

F

OFF

5

4

3

2

1

O

F

F

P

ilo

t

3/8" - 1/2"

This manual is related to the following products: